Operator's Manual
Seventh Edition • First Printing
Operating Instructions
52 Z
®
-45J DC • Z
®
-45J Bi-Energy
Part No. 1307436GT
Standard Batteries
1
Remove the battery vent caps and check the
battery acid level. If necessary, add only
enough distilled water to cover the plates. Do
not overfill prior to the charge cycle.
2
Replace the battery vent caps.
3
Connect the battery charger to a grounded AC
circuit.
4
The charger will indicate when the battery is
fully charged.
5
Check the battery acid level when the charging
cycle is complete. Replenish with distilled
water to the bottom of the fill tube. Do not
overfill.
Dry Battery Filling and Charging
Instructions
1
Remove the battery vent caps and
permanently remove the plastic seal from the
battery vent openings.
2
Fill each cell with battery acid (electrolyte) until
the level is sufficient to cover the plates.
Do not fill to maximum level until the battery charge
cycle is complete. Overfilling can cause the battery
acid to overflow during charging. Neutralize battery
acid spills with baking soda and water.
3
Install the battery vent caps.
4
Charge the battery.
5
Check the battery acid level when the charging
cycle is complete. Replenish with distilled
water to the bottom of the fill tube. Do not
overfill.