Operator's Manual
Seventh Edition • First Printing
Inspections
34 Z
®
-45J DC • Z
®
-45J Bi-Energy
Part No. 1307436GT
At the Platform Controls
17
Pull out the red Emergency Stop button to the
on position.
18
Bi-Energy models: Start the engine. See
Operating Instructions section.
Test Emergency Stop
19
Push in the platform red Emergency Stop
button to the off position.
Result: The engine (if equipped) should turn
off.
20
Activate each machine function control handle
or toggle switch.
Result: No functions should operate.
21
Pull out the red Emergency Stop button to the
on position.
Test the Horn
22
Press the horn button.
Result: The horn should sound.
Test the Foot Switch
23
Do not press down the foot switch.
Result: No functions should operate.
Test Machine Functions and Descent
Alarm
24
Press down the foot switch.
25
Activate each machine function control handle
or toggle switch.
Result: All boom and platform functions should
operate through a full cycle. The descent alarm
should sound while the boom is lowering.
Test the Steering
26
Press down the foot switch.
27
Press the thumb rocker switch on top of the
control handle in the direction indicated by the
blue triangle on the control panel.
Result: The steer wheels should turn in the
direction that the blue triangles point on the
drive chassis.
28
Press the thumb rocker switch on top of the
control handle in the direction indicated by the
yellow triangle, on the control panel.
Result: The steer wheels should turn in the
direction that the yellow triangles point on the
drive chassis.
Summary of Contents for Genie Z-45 BE
Page 65: ......