Inspections
38 Z
®
-45J DC • Z
®
-45J Bi-Energy
Part No. 1307436GT
Test the Contact Alarm (if equipped)
69
Do not activate the foot switch and press on
the contact alarm cable to release the actuator
from the switch socket.
Result: The contact alarm lights will not flash
and the machine horn will not sound.
70
Activate the foot switch by pressing the foot
switch down.
Result: The contact alarm lights will flash and
the machine horn will sound.
71
Insert the actuator into the switch socket.
Result: The lights and horn will turn off.
72
Activate the foot switch by pressing the foot
switch down and press on the contact alarm
cable to release the actuator from the switch
socket.
Result: The contact alarm lights will flash and
the machine horn will sound.
73
Operate each machine function.
Result: All machine functions should not
operate.
74
Insert the actuator into the switch socket.
Result: The lights and horn will turn off.
75
Operate each machine function.
Result: All machine functions should operate.
a
actuator
b
contact alarm cable
c
flashing alarm
d
switch socket
Test Auxiliary Lowering
76
Pull out the red Emergency Stop button to the
on position.
77
Press down the foot switch.
78
Simultaneously hold the auxiliary power switch
on and activate each function control handle or
toggle switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom and steer functions should
operate. Drive functions should not operate
with auxiliary power.