Operation from Ground
1
Turn the key switch to ground control.
2
Pull out the red Emergency Stop button to the
on position.
To Position Platform
1
Hold the function enable switch
to either side.
2
Move the appropriate toggle switch according
to the markings on the control panel.
Drive and steer functions are not available from the
ground controls.
Platform Overload Indicator Light
Light flashing indicates the platform is overloaded.
The engine will stop and no functions will operate.
Remove weight from the platform until the light
goes off and then restart the engine.
Note: An alarm will sound at the platform when an
overload condition occurs and will stop sounding
when weight is removed from the platform.
Operation from Platform
1
Turn the key switch to platform control.
2
Pull out both ground and platform red
Emergency Stop buttons to the on position.
To Position Platform
1
Set the boom function speed controller to the
desired speed.
Note: Drive and steer functions are not affected by
the boom function speed controller.
2
Press down the foot switch.
3
Move the appropriate toggle switch according
to the markings on the control panel.
To Steer
1
Press down the foot switch.
2
Turn the steer wheels with the thumb rocker
switch located on the top of the control handle.
Use the color-coded direction triangles on the
platform controls and the drive chassis to identify
the direction the wheels will turn.