Operator's Manual
Fifth Edition • Second Printing
Part No. T113597
S-100 • S-105 • S-120 • S-125
47
Operating Instructions
Platform Overload
Flashing light indicates the platform is
overloaded. The engine will stop and
no functions will operate.
Remove the weight from the platform
until the light goes off and then restart
the engine.
Out of Operational Envelope
Recovery
If all functions stop operating, you may have
exceeded the operational envelope.
Retract Boom indicator light is flashing: Use the
Auxiliary Power Unit at the platform to retract the
boom until the indicator light is off. Restart the
engine to continue operation.
Raise Boom indicator light is flashing: Use the
Auxiliary Power Unit at the platform to raise the
boom until the indicator light is off. Restart the
engine to continue operation.
If the Auxiliary Power Unit at the platform
does not function, a trained operator on the
ground will need to lower the platform from
the ground controls. Please see the Service
Bypass / Recovery Key Switch section in the
service manual.
Generator (if equipped)
To operate the generator, press the generator
button. The indicator light will come on and the
engine will continue to run.
Plug power tools into the power to platform GFCI
outlet.
To turn off the generator, push the generator
button. The indicator light will turn off.