Third Edition • First Printing
Operator's Manual
Inspections
Part No. 1305656GT
GS
™
-
2669BE • GS
™
-
3369BE • GS
™
-4069BE
27
At the Ground Controls
1
Select a test area that is firm, level and free of
hazards.
2
Be sure the batteries are connected.
3
Pull out the platform and ground red
Emergency Stop button to the on position.
4
Turn the key switch to ground control.
5
Observe the diagnostic LED readout on the
platform controls.
Result: The LED should look like the picture
below.
6
Observe the diagnostic LCD readout on the
ground controls.
Result: The LCD should display the model and
hour meter.
Test Emergency Stop
7
Start the engine.
8
Push in the red Emergency Stop button to the
off position.
Result: The engine should shut off and no
functions should operate.
9
Pull out the red Emergency Stop button to the
on position and restart the engine.
Test the Up/Down Functions
The audible warnings on this machine and the
standard horn all come from the same central alarm.
The horn is a constant tone. The descent alarm
sounds at 60 beeps per minute. The alarm sounds
at 180 beeps per minute when the machine is not
level.
10
Do not press the lift function enable button.
11
Press the platform up or platform down button.
Result: The lift function should not operate.
12
Do not press the platform up or platform down
buttons.
13
Press the lift function enable button.
Result: The lift function should not operate.
14
Press and hold the lift function enable button,
and press the platform up button.
Result: The platform should raise.
15
Press and hold the lift function enable button,
and press the platform down button.
Result: The platform should lower. The descent
alarm should sound while the platform is
lowering.