Service Manual
May 2015
Checklist B Procedures
30
GS-2669 BE • GS-3369 BE • GS-4069 BE
Part No. 1257106
B-5
Test the Emergency Stop
Genie requires that this procedure be performed
every 250 hours or quarterly, whichever comes
first.
A properly functioning Emergency Stop button is
essential for safe machine operation. An
improperly operating red Emergency Stop button
will fail to shut off power and stop all machine
functions, resulting in a hazardous situation.
As a safety feature, selecting and operating the
ground controls will override the platform controls,
except the platform red Emergency Stop button.
1 Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position at both the ground and platform
controls.
2 Push in the red Emergency Stop button at the
ground controls to the off position.
Result: No machine functions should operate.
3 Turn the key switch to platform control and pull
out the red Emergency Stop button to the on
position at both the ground and platform
controls.
4 Push down the red Emergency Stop button at
the platform controls to the off position.
Result: No machine functions should operate.
Note: The red Emergency Stop button at the
ground controls will stop all machine operation,
even if the key is switched to platform control.
Note: If in ground controls mode and the red
Emergency Stop button at the platform controls is
pushed in, the ground controls LCD will display,
Platform EStop Depressed. The machine alarm will
sound at 1 beep per second.
B-6
Test the Key Switch
Genie requires that this procedure be performed
every 250 hours or quarterly, whichever comes
first.
Proper key switch action and response is essential
to safe machine operation. The machine can be
operated from the ground or platform controls and
the activation of one or the other is accomplished
with the key switch. Failure of the key switch to
activate the appropriate control panel could cause
a hazardous operating situation.
Note: Perform this procedure from the ground
using the platform controls. Do not stand in the
platform.
1 Pull out the red Emergency Stop button to the
on position at both the ground and platform
controls.
2 Turn the key switch to platform control.
3 Check the platform up/down function from the
ground controls.
Result: The machine functions should not
operate.
4 Turn the key switch to ground control.
5 Check the machine functions from the
platform controls.
Result: The machine functions should not
operate.
6 Turn the key switch to the off position.
Result: No function should operate.
Summary of Contents for Genie GS-2669 BE
Page 1: ...Service Manual GS 2669 BE GS 3369 BE GS 4069 BE Part No 1257106 Rev A3 May 2015...
Page 27: ...May 2015 Service Manual Specifications Part No 1257106 GS 2669 BE GS 3369 BE GS 4069 BE 11...
Page 100: ...Service Manual May 2015 Manifolds 84 GS 2669 BE GS 3369 BE GS 4069 BE Part No 1257106...
Page 173: ...May 2015 Service Manual 157 Contactor Box Layout All Models...
Page 176: ...Service Manual May 2015 160 Ground Control Box Layout All Models...
Page 177: ...May 2015 Service Manual 161 Platform Control Box Layout All Models...
Page 180: ...Service Manual May 2015 164 Generator Wiring Diagram All Models...
Page 185: ...May 2015 Service Manual 169 Electrical Schematic GS 4069 BE with 2 Speed Lift ANSI CSA...
Page 188: ...Service Manual May 2015 172 Electrical Schematic GS 4069 BE with Proportional Lift ANSI CSA...
Page 193: ...May 2015 Service Manual 177 Electrical Schematic GS 4069 BE with 2 Speed Lift AS CE...
Page 196: ...Service Manual May 2015 180 Electrical Schematic GS 4069 BE with Proportional Lift AS CE...
Page 197: ...May 2015 Service Manual 181 Hydraulic Schematic GS 2669 BE and GS 3369 BE with 2 Speed Lift...
Page 201: ...May 2015 Service Manual 185 Hydraulic Schematic GS 4069 BE with 2 Speed Lift...
Page 205: ......