November 2006
30
AL4000 Light Tower
Part No. 833002 Rev A
TROUBLESHOOTING
TROUBLE
POSSIBLE CAUSE
REMEDY
11.Lamp will not start
e.Improper ballast
e.The ballast name plate data should
agree with the line voltage and lamp
used. If not, replace the ballast.
f.Lamp has been operating; cool
f.Switch off breaker and allow lamp
down time insufficient
to cool.
12.Lamp starts slowly (arc does
a.Defective lamp
a.Lamp may glow for an extended
not strike when switch is first
period of time. Replace after
turned on
checking voltage and ballast
13.Circuit breaker trips on lamp
a.Short circuit or ground
a.Check wiring against diagram.
startup
inspect for shorts or ground. Fix as
needed.
14.Lamp light output low
a.Normal lamp depreciation
a.Replace lamp
b.Dirty lamp or fixture
b.Clean lamp and fixture
c.Defective ballast
c.Interchange ballast plugs. If lamp
starts, replace ballast. Check for
swollen capacitors, charred wiring,
core and coil, or other signs of
excessive heat.
d.Wrong voltage
d.Check line voltage at ballast input.
Voltage should be within 10% of
e.Improper ballast
e.Check ballast name plate against
lamp data
15.Lamp colors different
a.Normal lamp depreciation
a.Replace lamp
b.Dirty lamp or fixture
b.Clean lamp and fixture
c.Wrong lamp
c.Check data on lamps and replace
as needed.
16.Arc tube discolored or swollen
a.Over voltage from power supply
b.Improper ballast
b.Check ballast name plate against
lamp data
17.Short lamp life
a.Lamp damaged
a.Check for outer bulb cracks,
cracks where lamp meets base, and
for broken arc tube or loose metal
parts. Replace as needed.
b.Improper ballast
b.Check ballast name plate against
lamp data
18.Lamp flickers or goes out-
a.Improper Ballast
a.Check ballast name plate against
intermittent or cycling
lamp data
b.New lamp
b.Under certain conditions new lamps
may "cycle". Usually after 3 tries to
start at 30 to 60 second intervals,
lamp will stabilize and operate normal
rating when operating at normal load.
Check wiring connections for voltage
loss. Check socket contact point.
a.Check voltage at ballast, for current
or voltage surges, for shorted
capacitors and replace as needed
Summary of Contents for 833002
Page 25: ...November2006 Part No 833002 Rev A AL4000LightTower 25 SPECIFICATIONS DIMENSIONS...
Page 36: ...November2006 36 AL4000LightTower Part No 833002 Rev A MODEL NUMBER IDENTIFICATION...
Page 43: ...November2006 Part No 833002 Rev A AL4000LightTower 43 Wiring Diagrams Section...
Page 44: ...November2006 44 AL4000LightTower Part No 833002 Rev A FixtureWiring Diagram...
Page 45: ...November2006 Part No 833002 Rev A AL4000LightTower 45 1000MH Ballast Diagram...
Page 46: ...November2006 46 AL4000LightTower Part No 833002 Rev A 1000HPS Ballast Diagram...
Page 47: ...November2006 Part No 833002 Rev A AL4000LightTower 47 AC Wiring For A Light Tower Diagram...
Page 48: ...November2006 48 AL4000LightTower Part No 833002 Rev A DC Engine Wiring Diagram...
Page 49: ...November2006 Part No 833002 Rev A AL4000LightTower 49 AC Light Tower Wiring Diagram Perkins...
Page 50: ...November2006 50 AL4000LightTower Part No 833002 Rev A Consolidated Coil Cord With Plug End...
Page 51: ...November2006 Part No 833002 Rev A AL4000LightTower 51 Parts Catalog Section...
Page 56: ...November2006 56 AL4000LightTower Part No 833002 Rev A AXLE ASSEMBLY...
Page 58: ...November2006 58 AL4000LightTower Part No 833002 Rev A CABINET ASSEMBLY...
Page 60: ...November2006 60 AL4000LightTower Part No 833002 Rev A CABINET ASSEMBLY TOP DOORS...
Page 70: ...November2006 70 AL4000LightTower Part No 833002 Rev A TOWER BASE ASSEMBLY...
Page 72: ...November2006 72 AL4000LightTower Part No 833002 Rev A WINCH LOCK ASSEMBLY...
Page 78: ...November2006 78 AL4000LightTower Part No 833002 Rev A ELECTRICAL CONTROL BOX ASSEMBLY...
Page 80: ...November2006 80 AL4000LightTower Part No 833002 Rev A MH HPS LIGHT FIXTURE ASSEMBLY...