November 2006
Part No. 833002 Rev A
AL4000 Light Tower
29
TROUBLESHOOTING
TROUBLE
POSSIBLE CAUSE
REMEDY
6.Engine runs but produces a
a.Crankcase oil level is too high
a.Drain oil to its proper level
dense smoke
b.Low compression
b.Have a trained mechanic
inspect for broken or seized
rings. Inspect valve clearances
7.Engine overheats
a.Blocked cooling air intakes
a.Inspect the front and rear intakes
and clear as needed
b.Low coolant levels
b.Replace the coolant with a 50%
water/coolant solution
c.Radiator fins have become
c.Clear the radiator fins
clogged
d.Fan belt is loose
d.Tighten fan belt
8.Engine runs but the battery
a.Alternator has failed
a.Have a trained mechanic inspect
voltage is low
the alternator
9.Engine runs but the lights will
a.Circuit breakers are tripped
a.Reset the circuit breaker
not operate
b.Loose connections in the wiring
b.Have a trained electrician inspect
system
the ballast box wiring system
c.Burned out bulb
c.Replace the bulbs as needed
d.Defective capacitor
d.Have a trained electrician inspect
(Leroy Somers Generator)
the capacitor
e.Defective AC generator
e.Have a trained electrician inspect
the generator
f.Engine speed is too low
f.Have a trained mechanic inspect
the engine speed and reset to
1800rpm @ 60hz
g.Defective ballast and capacitors
g.Have a trained electrician inspect
the ballast and capacitors
10.Unusual noise coming from
a.The generator has a defective
a.Have a trained electrician inspect
the generator
bearing or damaged fan blade
the generator
11.Lamp will not start
a.Lamp loose in socket
a.Inspect lamp base to see if there
is arcing at center contact button.
Tighten lamp. Check socket for
damage. Replace if needed.
b.Floodlight plugs not tight
c.Defective ballast
c.Interchange ballast plugs. If lamp
starts, replace ballast. Check for
swollen capacitors, charred wiring,
core and coil, or other signs of
excessive heat.
d.Low voltage
d.Check line voltage at ballast input.
Voltage should be within 10% of
b.Check plug and receptacle. Tighten
if needed. Make sure power is off.
rating when operating at normal load.
Increase supply voltage or remove
external load.
Summary of Contents for 833002
Page 25: ...November2006 Part No 833002 Rev A AL4000LightTower 25 SPECIFICATIONS DIMENSIONS...
Page 36: ...November2006 36 AL4000LightTower Part No 833002 Rev A MODEL NUMBER IDENTIFICATION...
Page 43: ...November2006 Part No 833002 Rev A AL4000LightTower 43 Wiring Diagrams Section...
Page 44: ...November2006 44 AL4000LightTower Part No 833002 Rev A FixtureWiring Diagram...
Page 45: ...November2006 Part No 833002 Rev A AL4000LightTower 45 1000MH Ballast Diagram...
Page 46: ...November2006 46 AL4000LightTower Part No 833002 Rev A 1000HPS Ballast Diagram...
Page 47: ...November2006 Part No 833002 Rev A AL4000LightTower 47 AC Wiring For A Light Tower Diagram...
Page 48: ...November2006 48 AL4000LightTower Part No 833002 Rev A DC Engine Wiring Diagram...
Page 49: ...November2006 Part No 833002 Rev A AL4000LightTower 49 AC Light Tower Wiring Diagram Perkins...
Page 50: ...November2006 50 AL4000LightTower Part No 833002 Rev A Consolidated Coil Cord With Plug End...
Page 51: ...November2006 Part No 833002 Rev A AL4000LightTower 51 Parts Catalog Section...
Page 56: ...November2006 56 AL4000LightTower Part No 833002 Rev A AXLE ASSEMBLY...
Page 58: ...November2006 58 AL4000LightTower Part No 833002 Rev A CABINET ASSEMBLY...
Page 60: ...November2006 60 AL4000LightTower Part No 833002 Rev A CABINET ASSEMBLY TOP DOORS...
Page 70: ...November2006 70 AL4000LightTower Part No 833002 Rev A TOWER BASE ASSEMBLY...
Page 72: ...November2006 72 AL4000LightTower Part No 833002 Rev A WINCH LOCK ASSEMBLY...
Page 78: ...November2006 78 AL4000LightTower Part No 833002 Rev A ELECTRICAL CONTROL BOX ASSEMBLY...
Page 80: ...November2006 80 AL4000LightTower Part No 833002 Rev A MH HPS LIGHT FIXTURE ASSEMBLY...