XM974-V1.0-NR
- 5 -
a hibernation mode that will electronically discontinue all fixture functionality with
the exception of a few menu commands. The fixture will continue to enter
hibernation mode until the lamp is replaced and the lamp clock has been reset.
Before replacing the lamp let the lamp cool down, because during operation, the lamp can
reach very high temperature.
During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a
cloth to handle the lamps during insertion and removal.
Do not install lamps with a higher wattage. They generate higher temperatures than which the
device was designed for.
For the installation, you need one: PLATINUM 2R
Procedures:
1)
Plz put the fixtures on smooth desk ,Release the screw A,B,C. The open the plate for lamp-socket .
2)
Before you take off the lamp ,plz release the two wire which.
3)
Make the lamp move from left to right untill the lamp be took off .Plz wrap the lamp with the soft cloth
which go with the lamp to avoid your finger touching the glass part of lamp directly .
4)
Replace lamp .Plz noted that the lamp only have one installation direction.Make sure the replace lamp has
same installation dtrection with old lamp.
5)
Replace the plate for lamp socket .And tightening screw A,B,C.
6)
Plz reset the lamp time .Otherwise it will tigger the protecting firmware of system and make the lamp can
not self-close .
Please remember the lamp is not a hot-restrike type, you must wait for approximately 10
minutes after having turned off the lamp before you can turn it back on again.
Do not operate this device with open cover
4.2) Mounting the device
The applicable temperature for the lighting is between -10°C to 45°C. Do not use the lighting
under or above the temperature.