CleanIng and replaCIng the aIr FIlter
The projector has two kinds of filters inside. Please check and clean the filters periodically.
When the indicators or a message prompts you to clean the filter, comply with it as soon
as possible. If the filters are damaged or heavily soiled, replace them with the new ones.
To prepare the new filters, contact Teq with the following type number:
type number : UX37191 (Filter set)
When you replace the lamp, please replace the air filter. An air filter of specified type will
come together with a replacement lamp for this projector.
1. Turn off the projector, and unplug the power cord. Allow
the projector to sufficiently cool down.
2. Use a vacuum cleaner on and around the filter cover.
3. Slide the filter unit upward to take it off from the
projector.
4. Use a vacuum cleaner for the filter vent of the projector.
5. Take the fine meshed filter out while holding the filter
cover. It is recommended to leave the coarse meshed
filter in the filter cover as it is.
6. Use a vacuum cleaner on both sides of the fine meshed
filter while holding it so it will not be sucked in. Use a
vacuum cleaner for the inside of the filter cover to clean
up the coarse meshed filter. If the filters are damaged or
heavily soiled, replace them with new ones.
7. Put the fine meshed filter on the coarse meshed one,
turning its stitched side up.
8. Put the filter unit back into the projector.
9. Turn on the projector and reset the filter time using the
FILTER TIME item in the EASY MENU.
(1) Press the
MenU
button to display a menu.
(2) Point at the FILTER TIME using the
/
button, then press the
button. A dialog
will appear.
(3) Press the
button to select “OK” on the dialog. This will reset the filter time.