Programming Parameter:
Selecting Time Base & Modes:
3
Prog. end
Sec: Second : 000.0....599.9
Min: Minute : 00.00....99.59
Hour: Hours : 00.00....99.59
Select mode of operation.
Power-on Reset:
Yes: Timer SET value is reset.
No: Loads Timer value & OUT status
at the latest power failure after
the first power on.
Enter fixed password; 162.
Lower
Display
Lower
Display
Lower
Display
Lower
Display
Programming Timer SET Value:
SET
Press for 3 sec.
Upper Display
t.SEt
Set Value
Upper Display
Upper Display
Set Value
Set Value
SET
SET
Prog. end
t.oFF
Prog. end
t.on
If Out is selected as; 0, 2, 3, 4.
Second : 000.0....599.9
Minute : 00.00....99.59
Hours : 00.00....99.59
If Out is selected as; 1.
Second : 000.0....599.9
Minute : 00.00....99.59
Hours : 00.00....99.59
If Out is selected as; 1.
Second : 000.0....599.9
Minute : 00.00....99.59
Hours : 00.00....99.59
Lower
Display
Out = 1
Lower
Display
Lower
Display
+
SET
Press for 3 sec.
Upper Display
Upper Display
Upper Display
Upper Display
SET
t.bAS
Sec, Min, Hour
SET
Out
0....7
SET
P.rES
Yes, no
SET
CodE
Enter 162
Front Panel RESET:
Press for 2 sec.
RESET