9
TENNANT V-WD-24P
EN
USE OF THE SWITCHED
RECEPTACLE
WARNING: Switched receptacle is
only for connection of submersible
pump. Max Amperage: 5.9 A.
The switched receptacle is only designed
for the pump and float switch cords.
Connect the pump and float switch cords
to the receptacle as shown.
WET VACUUMING
Pump restrictions
- Solids Handling ½”
-
Liquid Temperature Range 32°F - 120°F
(0°C - 49°C)
Do not leave the machine unattended
when operating: turn off the motor
switches immediately if the float
valve closes suction.
Soil can deposit and lead to
malfunctions. Pump clear water or
thoroughly rinse the pump after
every use.
Check float valve looking for
damages and replace it if necessary
WARNING: Always disconnect the
power source before performing
maintenance on the pump. Failure
to do so may result in fatal electrical shock.
WARNING: Fasten or hold drain
hose securely while draining due to
high pressure water force.
MODE 1: WET PICK UP
1. Turn the motor switch on.
2. Using the accessory tool, pick up liquids
until tank is full. Turn off motor switch
immediately when float valve closes
suction.
3. Push machine to nearest floor drain.
4. Remove tank drain hose from holder, twist
off knob and drain. To drain tank using
pump, see MODE 2.
NOTE: Be certain the tank drain hose knob is
snug to prevent suction loss.
MODE 2: WET PICK UP USING PUMP
1. Connect the pump switch cord and the
float valve switch cord into the switched
receptacle on machine.
2. Connect the desired pump drain hose
fitting (included) to the camlock coupling.
3. Mount the camlock coupling at rear of
machine.
4. Connect the pump drain hose (not
included) to the hose fitting and route the
drain hose to the draining area.
5. Turn on the motor switch and pump switch.
6. Using accessory tool, start picking up
liquids. The pump will automatically turn
WARNING: Risk of injury. This is a
switched receptacle and is
energized when turned ON
CAUTION - Risk of fire. Do not
exceed 5.9 Amps.
USE OF SQUEEGEE ATTACHMENT
KIT (OPTIONAL)
Kit Part Number KTRI05342
1. Connect the vacuum hose to the squeegee
assembly.
2. Loop the hose and attach it to the plastic
clip.
3. Lift foot pedal with toe to release squeegee
from raised position.
4. Turn the motor switch on.
5. Pull the machine backwards to pick up
liquid.