R14 – Self Test Mode
TO ENTER:
• Press and hold ReadySpace & Extraction Buttons
• Turn key switch ON
• Release Buttons after the relay clicks
• The entire Self Test takes approximately 40 seconds
• At the Start of the Self Test, the Front Brush motor turns ON
• At the End of the Self Test, the Horn sounds
AFTER THE SELF TEST IS COMPLETE:
• If the Battery LED’s are blinking, NO FAULTS were found
• If any LED is blinking (other than Battery LED’s), an OPEN FAULT
was found (refer to diagram below)
• If any LED is lit solid, a SHORT FAULT was found refer to table
below (refer to diagram below)
ReadySpace Solenoid Valve Fault
Scrub Head Actuator Fault
Extraction Shoes Actuator Fault
Front Brush Motor Fault
Rear Brush Motor Fault
Vacuum Fan Motor Fault
Solution Pump Fault
Brake Solenoid Fault
Extraction Solenoid Valve Fault
ReadySpace Flush Solenoid Valve Fault
Horn Fault
All Systems OK
LED (Flashing = OPEN, Solid = SHORT)
System at Fault
Battery LED's Flashing
No Faults Found
ReadySpace LED
ReadySpace Solenoid Valve
Extraction LED
Extraction Solenoid Valve
Upper Speed (+) LED
Scrub Head Actuator
Lower Speed (-) LED
Extraction Shoes Actuator
Solution LED
Solution Pump
Upper Brush Pressure (+) LED
Front Brush Motor
Lower Brush Pressure (-) LED
Rear Brush Motor
Wand LED
Vacuum Fan Motor
Hose LED
ReadySpace Flush Solenoid Valve
Solution Tank Empty LED
Brake Solenoid
Recovery Tank Full LED
Horn/Back-up Alarm
Pu