R14 – Solution Pump & Solenoid Valves
(ReadySpace Mode)
Wiring Color Codes
(Unless otherwise marked)
0
1
2
3
4
5
6
7
8
9
Tan
Pink
Brown
Orange
Yellow
Green
Blue
Purple
Gray
White
Right Most Digit
of Wire Number
Color of Wire
= Battery Negative
or Logic Ground
= Battery Positive
or Positive Output
CONDITIONS: Key ON, ReadySpace button activated, propel pedal depressed
D2
POS
RIBBON CABLE CONNECTOR P6
CONTROL BOARD
STANDOFF 2
M1B
1 RED
NEG
50 RED
S1
M1A
D1
KEYSWITCH
RIBBON CABLE
-
50 RED
2
14
MAIN CONTACTOR
6
5
5
5
6
3
26
3
4
4
4
4
PIN J6-17
PIN J6-5
PIN J6-24
PIN J6-18
PIN J6-13
14
1 RED
POST J11
POST J7
CB1
5 A
CB2
15 A
+
F1
100 A
SW5
LEFT SIDE
DASH PANEL
13 BLK
PIN J6-25
SOLUTION PUMP
1 RED
13 BLK
+
-
6 VDC
+
-
6 VDC
+
-
6 VDC
+
-
6 VDC
STANDOFF 1
SW1
CHARGER
INTERLOCK
FLYBACK PATH
MTR7
PIN J6-6
14
TOUCH
PANEL
ReadySpace
Mode Button
48
PIN J6-4
PIN J6-19
14
14
14
14
F4
7.5A
22
SOL1
SOL2
SOL3
READYSPACE
SOLENOID VALVE
EXTRACTION
SOLENOID VALVE
READYSPACE
FLUSH SOLENOID
VALVE
51
16
46
!
Be cautious when working near Control Board -
Battery voltage is always present, even with Key OFF
During ReadySpace operation, the Flush Solenoid Valve (SOL3) will
activate every 2.5 minutes, for a duration of 3 seconds
i
EMERGENCY STOP
SWITCH (E-STOP)
R14 1032129 REV.01 (12-06)
41