R14 – Diagnostic & Configuration Modes
Mode
Entry Sequence
Indicator
Function
Upper Speed (+) LED blinks Tens of day of
month, Upper Brush Pressure (+) LED blinks
Single day of month
Lower Speed (-) LED blinks Tens of month,
Lower Brush Pressure (-) LED blinks Single
month
Solution Flow LED blinks Tens of year, Wand
Tool LED blinks out Single year
Self Test Mode
(Refer to page
48
for detailed
instructions for this mode)
Press and hold the
ReadySpace and Extraction
Buttons, turn key switch ON,
release buttons after the relay
clicks
Start of test - Front Brush motor turns ON
End of test - Horn sounds
All Battery LED's flashing indicate OK, A
Flashing LED (other than Battery LED's)
indicates an OPEN Fault, A Solid lit LED
indicates a SHORT Fault
Input Display Mode
(Refer to page
49
for detailed
instructions for this mode)
Press and hold Wand Tool
Button, turn key switch ON,
release button after forth
battery LED starts to blink
#4 battery LED blinks
Shows state of control board inputs from
various switches and sensors
Manual Mode
(Refer to page
50
for detailed
instructions for this mode)
Press and hold Solution Flow
Button, turn key switch ON,
release after third Battery LED
starts to blink.
#3 Battery LED blinks
Allows operation of individual functions
without the safety interlocks affecting or
controlling them
Propel/Brake Diagnostic
Mode
(Refer to page
51
for detailed
instructions for this mode)
Press and hold ReadySpace
and Speed Buttons, turn key
switch ON, release after battery
LED's are OFF
ReadySpace LED ON if in Forward
OR
Extraction LED ON if in Reverse - Brush
Pressure and Wand Tool LED's display
position of Propel Pedal, Speed and Solution
Flow LED's display position of Brake Pedal,
Battery LED's display Propel Motor current
level
Provides information regarding brake
pedal signal, propel pedal signal, and
propel motor current
Reverse Alarm
Select Mode
(Refer to page
53
for detailed
instructions for this mode)
Put directional switch in
Reverse, press & hold Horn
Button, turn key switch ON
Horn sounds or is silent
Allows enable/disable of
Backup alarm (Hospital Mode)
Display Software
Revision Mode
(Refer to page
47
for detailed
instructions for this mode)
Press and hold ReadySpace
Button, turn key switch ON,
wait 10 seconds, release
ReadySpace Button
Blinking LED’s indicate software revision
date
R14 1032129 REV.01 (12-06)
45