MAINTENANCE
255 SERIES II MM189 (12---89)
3-26
LPG FUEL TROUBLESHOOTING
Problem
Cause
Remedy
Engine will not start
Out of fuel
Replace fuel tank with full one
Service valve opened too
Close valve and reopen slowly
quickly --- engaging safety valve
Plugged fuel filter
Replace filter
Kinked or restricted fuel
Straighten or replace fuel line
line
Engine out of tune
Tune-up engine
Oil pressure switch failure
Replace oil pressure switch
Fuel lock valve failure
Repair or replace fuel filter lock
Vaporizer-regulator failure
Repair or replace
vaporizer-regulator
Engine runs unevenly
Wrong type of fuel
Replace vapor withdrawal tank
or lacks power
tank --- vapor withdrawal tank
with liquid withdrawal tank
Plugged fuel filter
Replace filter
Kinked or restricted fuel line
Straighten or replace fuel line
Engine out of tune
Tune-up engine
Restricted air filter
Clean or replace air filter
element
Vaporizer-regulator maladjusted
Adjust vaporizer-regulator
Summary of Contents for 255 Series II
Page 1: ...r 255 Series II Sweeper Scrubber...
Page 6: ...ABOUT THIS MANUAL 255 SERIES II MM189 12 89 d...
Page 16: ...GENERAL INFORMATION 255 SERIES II MM189 6 90 x...
Page 18: ...SPECIFICATIONS 255 SERIES II MM189 12 89 1 2...
Page 22: ...SPECIFICATIONS 255 SERIES II MM189 NIL 1 6...
Page 24: ...OPERATION 255 SERIES II MM189 12 89 2 2...
Page 60: ...OPERATION 255 SERIES II MM189 12 89 2 38...
Page 74: ...MAINTENANCE 255 SERIES II MM189 12 89 3 14 04624 HYDRAULIC SCHEMATIC LOW DUMP MODEL...
Page 75: ...MAINTENANCE 3 15 255 SERIES II MM189 12 89 04625 HYDRAULIC SCHEMATIC MULTI LEVEL DUMP MODEL...
Page 94: ...MAINTENANCE 255 SERIES II MM189 12 89 3 34 04642 ELECTRICAL SCHEMATIC ACCESSORIES...
Page 95: ...MAINTENANCE 3 35 255 SERIES II MM189 6 90 06187 ELECTRICAL SCHEMATIC AUTO SHAKER RFS...
Page 96: ...MAINTENANCE 255 SERIES II MM189 6 90 3 36 06187 ELECTRICAL SCHEMATIC AUTO SHAKER RFS...
Page 124: ...MAINTENANCE 255 SERIES II MM189 6 90 3 64...