Page 1: ...TRIAXIAL ELF Magnetic Field Meter TM 192 TM 192D HB4TM1920002 ...

Page 2: ... 7 Auto power off setup 8 8 Continuity data logging setup 9 9 Clear data logger memory 10 10 Clear all data logger memory 11 11 Single data memory 12 12 Viewing logged reading control key 12 13 Specifications 13 14 Battery replacement 14 15 External DC Power 14 16 Safety Precaution 15 17 Software installation 192D 15 18 Note 17 ...

Page 3: ...romagnetic field EMF The change in electric fields produces magnetic fields and the change in magnetic fields can also generate electric fields The fluctuation of correlation between each other is known as electromagnetic waves which is a form of energy similar to light and heat that can be transmitted either by radiation in the air or by an electric conductor It is suggested that rearrangements s...

Page 4: ...s capable of measuring the magnetic field radiation intensity that is produced from electric transmission equipment power lines microwave ovens air conditioners refrigerators computer monitors video audio devices and so forth z The magnetic field unit is Tesla T Gauss G milli Gauss mG or micro Tesla μT 1 T 10 000 G 1 G 1 000 mG 1μT 10 mG ...

Page 5: ... is a cost effective hand held instrument that was designed and calibrated to measure magnetic field radiation at different bandwidths from 30Hz to 2000Hz z Display microTesla uT or milliGauss mG units z Data hold HOLD maximum Hold MAX and minimum Hold MIN function z Auto range or manual range select mode z Datalogging capacity with Memory Size 500 data sets Model 192 or 9999 data sets Model 192D ...

Page 6: ... 5 Record data and Setup function left key 6 Range and Setup function up key 7 Reading and Setup function right key 8 Setup function key 9 Units and Setup function down key 10 Enter key 11 Calibration point for 12 Triple axis 13 External power DC 9V 14 USB interface TM 192D 15 Tripod mounting screw 16 Battery cover ...

Page 7: ...nual range mode is selected LCD will shown the mark The display of OL on the highest position indicates there is an overload on the reading Press to select a higher range for measurement again z The default value display is triaxial total magnetic field reading Press key to toggle between independent three single axis magnetic field readings and triaxial total magnetic field reading z To lock and ...

Page 8: ...nt field factors this magnetic field meter could display a reading value that is greater than 0 5 mG prior to measuring This is not a malfunction of the tester z With the tester in hand move slowly towards to the object under measurement until it is physically touched z Notice how the field intensity increases as you move closer to the object z If the power of object was turned off during the meas...

Page 9: ...6 Clock setup z This meter clock uses 24 hour time z Press key to enter clock setting mode 1 SET z Press or key to select option to adjust z Press or key to change the digit z Press key to store the setup exit the mode ...

Page 10: ...uto power off time setting mode 2 SET z Press or key to change the auto power off time z Press key to store the setup exit the mode z The auto power off time default value is 5 minutes Range is 0 to 99 minutes To cancel auto power off please set time to 0 minutes ...

Page 11: ... per instructions below To exit data logging set logging interval back to 0 z Press key again to enter continuous data logging interval setting mode 3 SET z Press or key to select option to adjust z Press or key to change the value z Press key to store the setup exit the mode Interval range is 0 seconds no data logging to 99 hours 99 minutes and 99 seconds ...

Page 12: ... TM 192D 10 Clear data logger memory last data entry z Press key again to clear data logger memory for last record setting mode 4 CLA z Press key to clear data logger memory for last record and exit the mode ...

Page 13: ...D 11 9 Clear ALL data logger memory z Press key again to clear data logger memory for all record setting mode 5 CLA z Press key to clear data logger memory for all record z Press key to store the setup exit the mode ...

Page 14: ...memory record z Press key each time to store the display reading and time stamp in memory 11 Viewing logged reading control key z Press key to view logged readings Press or key to scroll through the readings Press key to exit this mode ...

Page 15: ... at 50Hz 60Hz or 3 µT 3 0 30dgt at 50Hz 60Hz z Over load LCD display OL z Sample rate 2 5 times per second z Battery 9V NEDA 1604 IEC 6F22 or JIS 006P z Battery life Approximate 100 hours z Operating temperature humidity 5 to 40 below 80 RH z Storage temperature humidity 10 to 60 below 70 z Weight About 230g z Dimensions 173 L X80 W X32 H mm z Accessories User s manual 9V battery Carrying case MIN...

Page 16: ...V NEDA 1604 IEC 6F22 or JIS 006P size battery z Install the battery cover 14 External DC Power z External AC to DC adapter Voltage 9VDC 8 14VDCMax z Supply current 300Madc z Socket pin Positive Ground Casing External z Diameter 6 3mm internal Diameter 2 0 mm WARNING If the symbol appears on the LCD please replace the battery immediately ...

Page 17: ...the PC that will be connected to this meter z Please select the USB driver that will be installed such as E TM 192D PL 2303 Driver Installer exe windows 2000 SP4 windows XP SP2 click twice on the left key of the mouse to install the USB driver z Select the SETUP EXE i e E TM 192D SETUP EXE and installs the desktop icon z Remove the CD from PC after installation completed z Use the USB cable to con...

Page 18: ...tw eng downloads asp id 31 Select PL2303_Prolific_DriverInstaller_v1 5 0 zip Please select the USB driver that will be installed such as E PL 2303 Driver Installer exe windows 2000 SP4 windows XP SP2 click twice on the left key of the mouse to install the USB driver ...

Page 19: ...TM 192 TM 192D 17 17 Note Caution This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal ...

Page 20: ...TENMARS ELECTRONICS CO LTD 6F 586 RUI GUANG ROAD NEIHU TAIPEI 114 TAIWAN E mail service tenmars com http www tenmars com ...