Accuracy Specifications (2)
D Continuity Test
Range
Resolution
Accuracy
Overload Protection
400.0
Ω
0.1
Ω
Approximate
≤
100
Ω
1000Vp
Remarks:
••
Buzzer beeps continuously.
••
Open circuit voltage approximate 0.45V.
E. Diode Test
Range
Resolution
Overload Protection
Diode
1mV
100Vp
Remarks:
••
Open circuit voltage approximate 1.48V.
••
Displays approximate forward voltage drop reading 0.5V to 0.8V.
F. Capacitance
Range
Resolution
Accuracy
Overload Protection
40nF
10pF
Measure at REL mode
±(3% + 10)
1000Vp
400nF
100pF
±(3% + 5)
4nF
1nF
40nF
10nF
100nF
100nF
±(4% + 5)
G. Frequency & Duty Cycle
Range
Resolution
Accuracy
Overload Protection
10Hz to 10MHz
-
±(0.1% + 3)
1000Vp
0.1% to 99.9%
0.01%
-
Remarks:
•
10Hz to 10MHz Range:
≤≤
1MHz: 300mV rms
≤≤
input sensitivity
≤≤
30V rms;
>1MHz:600mV rms
≤≤
input sensitivity
≤≤
30V rms.
•
0.1% to 99.9%:
Reading is only for reference purpose.