background image

                                                         

72-7675

 

 

5)

 

The size of input wire and output wire. 

   

Input Wire Size 

Model 

115V 

230V 

Output Wire Size   

72-7675 

AWG#14 

0.75mm

2

 

AWG#18 

 

6)

 

An AC power cord is included with the unit. 

7)

 

The Selection of Output Test Lead: 

For  safety  assurance,  please  select  the  adequate  output  test 

lead according to the following list: 

Conductor 

UL 

(CSA) 
Model 

Wire 

No. 

AWG 

Component 

pc/mm 

Cross 

Section 

Area 

(mm)

2

 

Outer 

Diameter 

mm 

Maximum 

Conductive 

Resistor 

Ω

/km

 

Permissible 

Current 
A(amp) 

24 

11/0.16 

0.22 

0.64 

88.6 

7.64 

22 

17/0.16 

0.34 

0.78 

62.5 

10.0 

20 

21/0.18 

0.53 

0.95 

39.5 

13.1 

18 

34/0.18 

0.87 

1.21 

24.4 

17.2 

16 

26/0.254 

1.32 

1.53 

15.6 

22.6 

14 

41/0.254 

2.08 

2.03 

9.90 

30.4 

12 

65/0.254 

3.29 

2.35 

6.24 

40.6 

1015 

TEW 

(Twisted 

Wire) 

10 

65/0.32 

5.23 

3.00 

3.90 

55.3 

Remark: 

a)

 

The ambient temperature of  “Permissible  Current” is at 
40

,  the  withstanding  temperature  of  conductor  is  at 

105

  according  to  the  condition  of  the  distributed 

single wire. 

b)

 

The  permissible  current  listed  as  above  is  suggested  to 
be used under 70%. 

c)

 

When  the  current  value  exceeds  above  suggestive  list, 
can  select  more  wires  used  in  parallel  according  to 
above list.     

 

 
 
 

                                                         

72-7675

 

 

3. OPERATION 

 

Voltage Setting: 

Voltage  setting  contents  “110V”,  “220V”,  “

”  and  “

”  four 

keys. 

a.

 

When  any  one  of  the  keys  mentioned  above  is  pressed,  the 

voltage  display  will  flash  one  time,  the  unit  will  go  to  the 

setting mode and show the voltage setting value. 

b.

 

If  the  “110V”  Key  is  pressed,  the  output  voltage  will  be 

adjusted  to  110V  immediately.  Meanwhile,  the  voltage 

display will switch back to the reading mode automatically. 

c.

 

If  the  “220V”  key  is  pressed  for  0.2  seconds  continuously 

(for  safety  reason,  must  be),  the  output  voltage  will  be 

adjusted to 220V. Meanwhile, the voltage display will switch 

back to the reading mode automatically. 

Note:  It  will  not  work  if  the  output  voltage  is  setting  on 

low range (0~150V output) 

d.

 

If  either  “

”  or  “

”  key  is  pressed  for  0.5  seconds,  the 

output  voltage  will  be  adjusted.  If  either  “

”  or  “

”  is 

pressed  twice,  the  output  voltage  will  be  adjusted 

immediately. 

e.

 

The  adjusting  rates  are  0.1V/step  on  fine  adjust  mode  and 

1V/step on coarse adjust mode. 

f.

 

The  first  six  steps  of  adjustment  will  be  spent  0.25  seconds 

per  step.  If  the  key  “

”  or  “

”  is  pressed  continuously,  it 

will spend 0.13 second per step for the rest steps. If the key 

is released, the voltage adjustment would be stopped and go 

back to the original adjustment speed (0.25 seconds per step) 

automatically. 

g.

 

If  the  output  mode  is  setting  ON  (the  indicator  “OUTPUT” 

would  light),  the  output  voltage  could  follow  the  setting 

voltage simultaneously. 

Summary of Contents for 72-7675

Page 1: ...FETY TERMS AND SYMBOLS These terms may appear in this manual or on the product WARNING Warning statements identify condition or practices that could result in injury or loss of life Caution Caution statements identify conditions or practices that could result in damage to this product or other property The following symbol may appear in this manual or on the product Attention refer to Manual ...

Page 2: ... the rear panel 2 Before connecting the power cord to the suitable outlet please make sure all the 72 7675 s breakers are turned off It will avoid the unnecessary accident or damage to the unit 3 Plug the input power cord to the suitable outlet 4 Please make sure the input tolerance is within 10 of rated voltage see figure 1 72 7675 3 Figure 1 Max Output Voltage 150 300 120 240 100 200 85 90 95 11...

Page 3: ...ing contents 110V 220V and four keys a When any one of the keys mentioned above is pressed the voltage display will flash one time the unit will go to the setting mode and show the voltage setting value b If the 110V Key is pressed the output voltage will be adjusted to 110V immediately Meanwhile the voltage display will switch back to the reading mode automatically c If the 220V key is pressed fo...

Page 4: ...ing voltage to change however there is a 20ms interruption during the voltage range changing The non reasonable range changing For example the voltage sets 200V but the range is changed to the low range is not acceptable 72 7675 7 this unit Note High range voltage 0 300V Low range voltage 0 150V Instrumentation selection a Pressing the A key will light the current indicator and the LED display wil...

Page 5: ...isplayed Save Recall Function Press the key of S R if the indicator of SAVE RECALL doesn t light Press any one of MEM1 MEM2 MEM3 and MEM4 keys for 0 2 seconds the current output setting will be saved If the indicator of SAVE RECALL lights press any one of MEM1 MEM2 MEM3 and MEM4 keys for 0 2 seconds the setting saved last time by the same key will be recalled as current setting 72 7675 9 ...

Page 6: ...arse indicator does not light 72 7675 11 10 High Low Range Indicator of Output Voltage If this indicator lights the output voltage is in the range 0 300V If this Indicator does not light the output voltage is in the range 0 150V 11 27 110V and 220V Keys One touch key for 220V and 110V output respectively 12 Output Voltage LED Display If the OUTPUT Key is not pressed the indicator doesn t light and...

Page 7: ... form is generated by the digital synthesizer and filtered by a very high impedance filter Therefore the sine wave form will be very stable and the distortion will be reduced The unit has two voltage feedback systems One is analog feedback system for quick response within 100us and the regulation will be located in the range of 5 The other is digital feedback system The system will read the output...

Page 8: ...tion 0 1Vrms Accuracy 1 rdg 5digitAC0 0 40 0V Output Capacity Low voltage range 0 0 150Vac High voltage range 0 0 300Vac Output Power 500VA 72 7675 Maximum Current 72 7675 4 2A 0 150V 2 1A 0 300V Line Voltage Regulation 0 1 Load Regulation 0 5 0 1V Protection Key Lock OCP Short Circuit Protect OTP Frequency Stability 100ppm Wave Distortion 0 150V 22V 125V 0 5 THD Resistance Load 0 300V 44V 280V 0 ...

Page 9: ...ons 137mm H 430 W 500mm D Weight Approximate 25kgs 72 7675 17 8 MAINTENANCE Cleaning Use a soft cloth moistened with a small amount of water or mild detergent Do not spray cleaner directly onto the instrument as it may leak into the cabinet and cause damage Do not use chemicals containing benzine benzene xylene acetone toluene or similar solvents Do not use abrasive cleaners on any portion of this...