background image

                                                         

72-7675

 

 

14 

6. BLOCK DIAGRAM 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

I/P 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

Keyboard 

Display

 

Voltage 
Control 

Frequency 
Control 

Frequency 
Sensor 

Memory 

 

A/D 

Isolated 

Transformer 

Rect. / 

Filter 

Power 

Amplifier 

Sine wave   

Synthesizer 

Output 

Transformer

 

Current & 

Voltage 

Feedback

 

Current & 

Voltage 

Sensor 

O/P 

                                                         

72-7675

 

 

15 

7. SPECIFICATIONS 

 

Specification 

Description 

Output 
Frequency 
(45.0~500Hz) 

Digital setting via keys, Resolution: 0.1Hz 
Accuracy: ±0.1Hz 

Output Voltage 
(AC0.0~300.0V) 

Digital setting via keys, Resolution: 0.1Vrms 
Accuracy: ±1%rdg+1digit AC40.1~ 300.0V) 
 
Resolution: 0.1Vrms 
Accuracy: ±1%rdg+5digitAC0.0~ 40.0V)       

Output Capacity 

Low voltage range: 0.0    ~    150Vac   
High voltage range: 0.0    ~    300Vac 

Output Power 

500VA(72-7675);   

Maximum 
Current 

72-7675: 4.2A(0~150V), 2.1A(0~300V) 

Line Voltage   
Regulation 

±0.1% 

Load Regulation  ±(0.5%+0.1V) 
Protection 

Key Lock, OCP, Short Circuit Protect OTP 

Frequency 
Stability 

100ppm 

Wave Distortion 

0-150V 22V~125V

0.5%THD.(Resistance Load) 

0-300V 44V~280V

0.5%THD.(Resistance Load)

 

Digital Display: 

Frequency 
Counter 

Measuring Range

0.0~999Hz 

Resolution

0.1Hz 

Accuracy

±0.1Hz 

RMS Voltmeter 

Measuring Range

AC0.0 ~ 380V 

Resolution

0.1Vrms   

Accuracy

±1% Rdg+1Digit 

RMS Ammeter 

Measuring Range:  0.000~2.000A  1.80~35.00A 

Resolution: 

1mA(<360w) 

0.01A 

Accuracy: 

±1% rdg 

+5 digits 

±1% rdg 

+2 digits 

 

Summary of Contents for 72-7675

Page 1: ...FETY TERMS AND SYMBOLS These terms may appear in this manual or on the product WARNING Warning statements identify condition or practices that could result in injury or loss of life Caution Caution statements identify conditions or practices that could result in damage to this product or other property The following symbol may appear in this manual or on the product Attention refer to Manual ...

Page 2: ... the rear panel 2 Before connecting the power cord to the suitable outlet please make sure all the 72 7675 s breakers are turned off It will avoid the unnecessary accident or damage to the unit 3 Plug the input power cord to the suitable outlet 4 Please make sure the input tolerance is within 10 of rated voltage see figure 1 72 7675 3 Figure 1 Max Output Voltage 150 300 120 240 100 200 85 90 95 11...

Page 3: ...ing contents 110V 220V and four keys a When any one of the keys mentioned above is pressed the voltage display will flash one time the unit will go to the setting mode and show the voltage setting value b If the 110V Key is pressed the output voltage will be adjusted to 110V immediately Meanwhile the voltage display will switch back to the reading mode automatically c If the 220V key is pressed fo...

Page 4: ...ing voltage to change however there is a 20ms interruption during the voltage range changing The non reasonable range changing For example the voltage sets 200V but the range is changed to the low range is not acceptable 72 7675 7 this unit Note High range voltage 0 300V Low range voltage 0 150V Instrumentation selection a Pressing the A key will light the current indicator and the LED display wil...

Page 5: ...isplayed Save Recall Function Press the key of S R if the indicator of SAVE RECALL doesn t light Press any one of MEM1 MEM2 MEM3 and MEM4 keys for 0 2 seconds the current output setting will be saved If the indicator of SAVE RECALL lights press any one of MEM1 MEM2 MEM3 and MEM4 keys for 0 2 seconds the setting saved last time by the same key will be recalled as current setting 72 7675 9 ...

Page 6: ...arse indicator does not light 72 7675 11 10 High Low Range Indicator of Output Voltage If this indicator lights the output voltage is in the range 0 300V If this Indicator does not light the output voltage is in the range 0 150V 11 27 110V and 220V Keys One touch key for 220V and 110V output respectively 12 Output Voltage LED Display If the OUTPUT Key is not pressed the indicator doesn t light and...

Page 7: ... form is generated by the digital synthesizer and filtered by a very high impedance filter Therefore the sine wave form will be very stable and the distortion will be reduced The unit has two voltage feedback systems One is analog feedback system for quick response within 100us and the regulation will be located in the range of 5 The other is digital feedback system The system will read the output...

Page 8: ...tion 0 1Vrms Accuracy 1 rdg 5digitAC0 0 40 0V Output Capacity Low voltage range 0 0 150Vac High voltage range 0 0 300Vac Output Power 500VA 72 7675 Maximum Current 72 7675 4 2A 0 150V 2 1A 0 300V Line Voltage Regulation 0 1 Load Regulation 0 5 0 1V Protection Key Lock OCP Short Circuit Protect OTP Frequency Stability 100ppm Wave Distortion 0 150V 22V 125V 0 5 THD Resistance Load 0 300V 44V 280V 0 ...

Page 9: ...ons 137mm H 430 W 500mm D Weight Approximate 25kgs 72 7675 17 8 MAINTENANCE Cleaning Use a soft cloth moistened with a small amount of water or mild detergent Do not spray cleaner directly onto the instrument as it may leak into the cabinet and cause damage Do not use chemicals containing benzine benzene xylene acetone toluene or similar solvents Do not use abrasive cleaners on any portion of this...

Reviews: