Caution: If there is no function test of voltage “

” or   

”,the  voltage  output  mode  would  be  suggested  to 

switch  to  “OFF”  status  for  avoiding  unnecessary 

mistakes occurring. 

 

h.

 

If  any  key  mentioned  above  is  not  pressed  for  2  seconds 

continuously,  the  unit  will  go  back  to  the  normal  operation 

and  the  voltage  display  could  show  the  reading  value 

automatically. 

 

Frequency Setting: 

Frequency setting contents 

“50Hz”, “60Hz”, “

” and “

” 

four 

keys. 

a.

 

If the key “

50Hz” 

or the key “

60Hz” 

is pressed

the frequency 

will  be  changed  immediately  to  50Hz,  60Hz  respectively. 

Meanwhile 

the 

output 

frequency 

will 

be 

changed 

coincidentally. 

b.

 

The frequency ranges from 45Hz to 99.9Hz can be adjusted by 

0.1 Hz per step in fine adjustment mode and 1 Hz per step in 

coarse adjustment mode. The frequency ranges from 100Hz to 

500Hz can be adjusted by 1 Hz per step in fine adjustment and 

10Hz per second in coarse adjustment mode. 

c.

 

The other settings are the same as voltage setting.

 

 

High / Low Voltage range selection: 

Press  the  key  of

  “RANGE”

,  if  the  indicator  lights,  the  output 

voltage would be setting on the high voltage range, otherwise, the 

system would be setting on low voltage range. The changed range 

would not cause the setting voltage to change, however, there is a 

20ms  interruption  during  the  voltage  range  changing.  The 

non-reasonable  range  changing  (For  example,  the  voltage  sets 

200V but the range is changed to the low range) is not acceptable 

                                                         

72-7675

 

 

this unit. 

Note: High range voltage 0 ~ 300V 

Low range voltage 0 ~ 150V

 

 

Instrumentation selection: 

a.

 

Pressing  the 

“A”

  key

 

will  light  the  current  indicator  and  the 

LED display will show the value of current. 

b.

 

Pressing the 

“W”

 will light the power indicator and the LED 

display will show the value of wattage. 

c.

 

Pressing  the 

“PF” 

key  will  light  the  power  factor  indicator 

and the LED display will show the value of power factor. 

 

Output Enabled and Disabled Operation: 

Press  the  key  of 

“OUTPUT”

.  If  the  output  indicator  lights,  the 

output is enabled, and the LED display will show the output value 

(reading value). Otherwise, the output function is disabled, and the 

LED display will show the setting value. Press the “OUTPUT” key 

again to change the mode.   

 

Lock Function: 

Press the key of “

LOCK”, 

if the lock indicator lights, all the keys 

are  Locked  (except  the  alarm  reset).  This  function  is  good  for 

avoiding any mistakes of key pressed during operation. Press again 

to change the mode. 
 

Alarm Reset: 

If  an  over  current  event  occurs,  the  72-7675  will  shut  down  and 

buzz immediately. You must press 

“ALARM RESET” 

to clear. In 

addition, the 

“OUTPUT” 

key must

 

be pressed to return to normal 

output voltage. 

 

Summary of Contents for 72-7675

Page 1: ...FETY TERMS AND SYMBOLS These terms may appear in this manual or on the product WARNING Warning statements identify condition or practices that could result in injury or loss of life Caution Caution statements identify conditions or practices that could result in damage to this product or other property The following symbol may appear in this manual or on the product Attention refer to Manual ...

Page 2: ... the rear panel 2 Before connecting the power cord to the suitable outlet please make sure all the 72 7675 s breakers are turned off It will avoid the unnecessary accident or damage to the unit 3 Plug the input power cord to the suitable outlet 4 Please make sure the input tolerance is within 10 of rated voltage see figure 1 72 7675 3 Figure 1 Max Output Voltage 150 300 120 240 100 200 85 90 95 11...

Page 3: ...ing contents 110V 220V and four keys a When any one of the keys mentioned above is pressed the voltage display will flash one time the unit will go to the setting mode and show the voltage setting value b If the 110V Key is pressed the output voltage will be adjusted to 110V immediately Meanwhile the voltage display will switch back to the reading mode automatically c If the 220V key is pressed fo...

Page 4: ...ing voltage to change however there is a 20ms interruption during the voltage range changing The non reasonable range changing For example the voltage sets 200V but the range is changed to the low range is not acceptable 72 7675 7 this unit Note High range voltage 0 300V Low range voltage 0 150V Instrumentation selection a Pressing the A key will light the current indicator and the LED display wil...

Page 5: ...isplayed Save Recall Function Press the key of S R if the indicator of SAVE RECALL doesn t light Press any one of MEM1 MEM2 MEM3 and MEM4 keys for 0 2 seconds the current output setting will be saved If the indicator of SAVE RECALL lights press any one of MEM1 MEM2 MEM3 and MEM4 keys for 0 2 seconds the setting saved last time by the same key will be recalled as current setting 72 7675 9 ...

Page 6: ...arse indicator does not light 72 7675 11 10 High Low Range Indicator of Output Voltage If this indicator lights the output voltage is in the range 0 300V If this Indicator does not light the output voltage is in the range 0 150V 11 27 110V and 220V Keys One touch key for 220V and 110V output respectively 12 Output Voltage LED Display If the OUTPUT Key is not pressed the indicator doesn t light and...

Page 7: ... form is generated by the digital synthesizer and filtered by a very high impedance filter Therefore the sine wave form will be very stable and the distortion will be reduced The unit has two voltage feedback systems One is analog feedback system for quick response within 100us and the regulation will be located in the range of 5 The other is digital feedback system The system will read the output...

Page 8: ...tion 0 1Vrms Accuracy 1 rdg 5digitAC0 0 40 0V Output Capacity Low voltage range 0 0 150Vac High voltage range 0 0 300Vac Output Power 500VA 72 7675 Maximum Current 72 7675 4 2A 0 150V 2 1A 0 300V Line Voltage Regulation 0 1 Load Regulation 0 5 0 1V Protection Key Lock OCP Short Circuit Protect OTP Frequency Stability 100ppm Wave Distortion 0 150V 22V 125V 0 5 THD Resistance Load 0 300V 44V 280V 0 ...

Page 9: ...ons 137mm H 430 W 500mm D Weight Approximate 25kgs 72 7675 17 8 MAINTENANCE Cleaning Use a soft cloth moistened with a small amount of water or mild detergent Do not spray cleaner directly onto the instrument as it may leak into the cabinet and cause damage Do not use chemicals containing benzine benzene xylene acetone toluene or similar solvents Do not use abrasive cleaners on any portion of this...