443 06 4001 01
5
Specifications subject to change without notice.
7. Connect the connector harness to gas valve.
NOTE
: Use only propane
−
resistant pipe dope. Do not use
Teflon tape.
8. Insert the gas pipe through the grommet in the casing.
Apply a thin layer of pipe dope to the threads of the pipe
and thread the pipe into the gas valve.
NOTE
: Use a back
−
up wrench on the gas valve to prevent the
valve from rotating on the manifold or damaging the mounting
to the burner box.
9. With a back
−
up wrench on the inlet boss of the gas
valve, finish tightening the gas pipe to the gas valve.
10. Check for leaks after the gas pipe is installed.
NOTE
: If you are converting furnace for use with propane,
attach kit labels and extra parts bag as described in Procedure
3 then proceed to Section II.
Procedure 3 — Label and Extra Parts Bag Attachment
NOTE
: See
Figure 6, Figure 7
and
Figure 8
for label location.
1. Attach Conversion Responsibility Label (337993
−
101)
inside of main furnace door. (See
Figure 7
) Date, name,
and address of organization making this conversion are
required. (See
Figure 5
)
2. Attach Conversion Rating Plate Label (338299
−
101)
inside of lower left
−
hand side of controls compartment
(downflow) as shown in
Figure 6
.
3. Attach Manufactured (Mobile) Home Installation Label
(322236
−
101) inside of main furnace door. (See
Figure 7
)
4. Attach adhesive pouch (337985
−
101) containing gas
orifices and Installation Instructions to front of main
furnace door or accessible furnace side. (See
Figure 1
or
Figure 8
)
5. Proceed to
Section II
or
III
for gas type modification and
Input rate adjustment.
Figure 5
Conversion Responsibility Label
Figure 6
Conversion Rating Plate Label Location
FURNACE CONVERSION
RATING PLATE
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY.
Figure 7
Installation & Responsibility Label Locations
RESPONSIBILITY LABEL
MANUFACTURED (MOBILE)
HOME INSTALLATION LABEL
INSIDE OF DOORS
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY.