background image

 

 

 

 

 

Breeze User Manual 

 

 

Wiring the Enclosure 

Power Wiring 

SAFETY NOTICE: 

All electrical wiring and termination MUST be carried out by 
a suitably qualified and/or licensed professional, in 
accordance with electrical and safety norms applicable in the 
jurisdiction of the installation. Tempest, its employees and 
representatives will not be liable for any damage arising 
from failure to observe this requirement. 

 

Electrical Standards 

Important: 

Fans and electronics are rated 115V or 230V, dependent on 
electrical standard. 

 

Enclosure model numbers ending .US are for use in countries 
using US and Japanese style electrical systems: 

 

100-120VAC 50/60Hz 

 

Enclosure model numbers ending .IN are for use in countries 
using European style electrical systems: 

 

200-230VAC 50/60Hz 

 

 

Remove the cover fixing screws, using a 4mm Hex Key. 

 

 

 

 

 

Lift off the top cover. 

 

4mm 

Summary of Contents for Breeze 52.050

Page 1: ...Breeze User Manual 1 User Manual Breeze Revision 01 1 September 2017 Tempest Lighting Inc...

Page 2: ...Breeze Enclosure 6 Wiring the Enclosure 7 Power Wiring 7 SAFETY NOTICE 7 Electrical Standards 7 Wiring Access 8 One or Two Power Circuits 9 3 4 Connect AC Wiring to MiniDEC Controller 10 Mounting the...

Page 3: ...Lifting some enclosures and the equipment inside them may be heavy Use properly rated lifting equipment where appropriate and never attempt to carry out work with fewer than the number of workers need...

Page 4: ...x150 16x16x6in 500W 52 050 Landscape 762 30in 595 23 5in 318 12 5in 648 25 5in 483 19in 21kg 45lb 610x521x229 24x20 5x9in 800W 52 100 Landscape 864 34in 702 27 6in 346 13 6in 749 29 5in 588 2 16in 30k...

Page 5: ...w 0 C 32 F Maximum ambient temperatures when the projector is running usually after dark should not be higher than 2 3 C below the projector s stated maximum environmental limit So for a projector wit...

Page 6: ...e of stainless steel mounting hardware Make sure the inlet filter has at least 75mm 3in clearance below IMPORTANT SAFETY NOTICES Installer must ensure that all mounting points are secure and conform t...

Page 7: ...ves will not be liable for any damage arising from failure to observe this requirement Electrical Standards Important Fans and electronics are rated 115V or 230V dependent on electrical standard Enclo...

Page 8: ...rminal AC Conduit Entry Projector Outlet AC Terminal Block Your Breeze enclosure comes with a rewirable C14 plug to fit this power outlet You MUST connect projector power to the C13 outlet If this is...

Page 9: ...ip most people use single feed Single Feed Enclosure and projector are permanently on Enclosure and Projector must be rated for the same voltage Supply must be rated for projector current plus 100 wat...

Page 10: ...ly The enclosure should be powered 24 7 The projector must be switched off when needed using the projector control system Breeze ships configured for single feed wiring operation Split Feed Wiring You...

Page 11: ...s to the desired height projector tilt and roll angles Align the projector then tighten the projector bails to hold it firmly in place Connecting Equipment Install the provided IEC C14 plug onto the p...

Page 12: ...ure inside the enclosure will start to rise This is an indication that the filter must be cleaned or replaced Clean Filter Remove filter and wash with water and a mild detergent Replacement Filters Pa...

Page 13: ...enclosure 1 Filter is either missing or damaged 2 Top cover is not properly seated Water in enclosure 1 Check the drain holes in the bottom of the enclosure If they become blocked then water that gets...