Breeze User Manual
13
Troubleshooting
Projector does not have power:
1.
Check Projector power switch
2.
Check projector is plugged into MiniDEC projector outlet
3.
Check that enclosure feed circuit is on
4.
Check voltage on AC input terminals
5.
Check voltage on IEC C13 outlet
Enclosure overheats:
1.
Is the projector connected to the MiniDEC projector
receptacle? If the projector is powered independently the
controller has no way to know when to turn on the
exhaust fans!
2.
Is the filter clogged or obstructed? If so, clean or replace
it.
Dirt/Debris inside enclosure
1.
Filter is either missing or damaged?
2.
Top cover is not properly seated
Water in enclosure
1.
Check the drain holes in the bottom of the enclosure. If
they become blocked, then water that gets in cannot
escape.
2.
Check seals around side panels and back door
Fan LED is on but fans do not operate
The exhaust fan is protected by a 20mm 4A slow-blow fuse on
the MiniDEC board. In very exceptional cases it is possible that
either fuse could fail. Check visually.
The fuse is protected with a clear resin sealant and soldered to
the circuit board. With care, you can de-solder the fuse and
replace it, but we recommend replacing the DEC4 motherboard
to maintain the integrity of the board’s conformal coating.
None of the above?
Contact