9.4. SIP parameters
Once the network parameters have been set correctly, you must configure the connection with the VoIP SIP PBX:
•
SIP server address
: specify the IP address of the SIP PBX to which AD639SR should connect.
•
Port
: is the port number of the SIP PBX with which AD639SR must operate. Generally it is the 5060, but
some stations use a different port.
•
Domain
: enter the domain to which register the system.
•
Outbound proxy
: some PBXs require that the extension number to call is followed by the proxy address. In
most cases this field can be left empty.
•
Local port
: generally the 5060 port is used, but it is possible to specify a different number (i.e. for particular
routing tables).
•
Expiration
: indicates how many seconds the device should check the correct registration of the client.
•
User/password
: credentials for the registration of the extension (which obviously must have been already
created on the PBX).
•
Ringer volume
: it is possible to set the volume used to reproduce the sound of Night Ringer. It is also the
volume used to reproduce the prerecorded announcements.
•
Ringer type
: it is possible to choose up to 6 pre-programmed ring tones in the device plus a customizable
one (that coincides with the default one). It is possible to change it in the maintenance page, see par.9.9
•
Test Ring ON-Test Ring OFF
: buttons that activate the ringer for the purpose of testing the sound emitted.
•
Increasing volume:
with this option, the volume will start low and will increase, due to no response over
time, until reaching the maximum volume set in "Ringtone volume".
•
Relay 1-2 activation
: it is possible to choose whether the 2 relays are to be activated during the call and in