Figure 2-10 NET-PATH Contact Sensor Option Strap Locations
Caution
If you do not have both option straps on a given sensor set
to the same pin numbers then the sensor will be non functional. If
you strap a sensor for RS423A input it will not support dry contact
applications or standard wet contact applications. It is advisable to
test each contact for proper operation after they are configured and
the NET-PATH unit is operational (database downloaded).
Note
The pin 1 designator for J59 is incorrect on the board. Pin
one is properly referenced by the black square. For a closer view of
the jumpers, see "Jumper Connections"‚ page 5-4.