Table 6 Electrical characteristics 

CHARACTERISTIC DESCRIPTION  

VALUE 

MIN.   TYP.   MAX.  

UNIT  

SUPPLY VOLTAGE

 

Supply Voltage (Recommended Operating 
Conditions)  

+10    

+30  

V  

DIGITAL OUTPUT (OPEN  DRAIN  GRADE)

 

Drain current (Digital Output OFF)  

 

 

120  

µA  

Drain current (Digital Output ON, Recommended 
Operating Conditions)  

 

0.1  

0.5  

A  

Static Drain-Source resistance (Digital Output ON)    

400  

600  

mΩ 

 

DIGITAL INPUT

 

Input resistance (DIN1)  

47  

 

 

kΩ 

 

Input resistance (DIN2)  

38.45   

 

kΩ 

 

Input resistance (DIN3)  

150 

 

 

kΩ 

 

Input voltage (Recommended Operating 
Conditions)  

0  

 

Supply 
voltage  

V  

Input Voltage threshold (DIN1)  

 

7.5  

 

V  

Input Voltage threshold (DIN2)  

 

2.5  

 

V  

Input Voltage threshold (DIN3)  

 

2.5  

 

V  

 

 

 

 

ANALOG  INPUT

 

Input voltage (Recommended Operating 
Conditions), Range 1  

0  

 

+10 

V  

Input resistance, Range 1  

 

38.45   

kΩ 

 

Measurement error on 12V, Range 1  

 

0.9  

 

 %  

Additional error on 12 V, Range 1  

 

108  

 

mV  

Measurement error on 30 V, Range 1  

 

0.33    

 %  

Additional error on 30 V, Range 1  

 

88  

 

mV  

Input Voltage (Recommended Operating 
Conditions), Range 2  

0  

 

+30  

V  

Input resistance, Range 2  

 

150 

 

kΩ 

 

Measurement error on 12 V, Range 2  

 

0.9  

 

 %  

Additional error on 12 V, Range 2  

 

108  

 

mV  

Measurement error on 30 V, Range 2  

 

0.33    

 %  

Additional error on 30 V, Range 2  

 

88  

 

mV  

OUTPUT SUPPLY VOLTAGE  1-WIRE

 

Supply voltage  

+4.5    

+4.7  

V  

Output inner resistance  

 

7  

 

Ω 

 

Output current (U

out

 > 3.0 V)  

 

30  

 

mA  

Short circuit current (U

out

 = 0)  

 

75  

 

mA  

NEGATIVE INPUT

 

Input resistance 

38.45   

  

kΩ 

 

Input voltage (Recommended Operating 
Conditions) 

 

Supply 
voltage 

V  

Input voltage threshold 

 

0.5 

 

V  

Sink current 

 

 

180 

nA  

Summary of Contents for FMM130

Page 1: ...Quick Manual v1 5 Advanced CAT M1 GSM GNSS BLE terminal with flexible inputs configuration FMM130...

Page 2: ...t the battery 6 PC Connection Windows 7 How to install USB drivers Windows 7 Configuration Windows 7 Quick SMS configuration 9 Mounting recommendations 10 LED indications 11 Characteristics 11 Basic c...

Page 3: ...3 FMM130 Wiki Know your device Figure 1 FMM130 device view...

Page 4: ...DIN 2 N AIN 1 Digital input channel 2 Negative input ground sense Analog input channel 1 Input range 0 30 VDC 5 DIN 1 Digital input channel 1 6 INPUT 6 TX EXT LVCAN TX 7 GND Ground pin 10 30 V DC 8 D...

Page 5: ...5 FMM130 Wiki Figure 3 FMM130 Wiring scheme Wiring scheme 1 Automotive relay 1...

Page 6: ...d or read our Wiki how to enter it later in Teltonika Configurator Make sure that Micro SIM card cut off corner is pointing forward to slot 3 Connect battery as shown to device Position the battery in...

Page 7: ...r installation window 4 In the following window click Install button Setup will continue installing the driver and eventually the confirmation window will appear Click Finish to complete the setup Con...

Page 8: ...y 1 Load from device loads configuration from device 2 Save to device saves configuration to device 3 Load from file loads configuration from file 4 Save to file saves configuration to file 5 Update f...

Page 9: ...detected by accelerometer Ignition will be detected by vehicle power voltage between 13 2 30 V Device makes a record On Moving if one of these events happen 300 seconds passes Vehicle turns 10 degree...

Page 10: ...on the car model this may happen in 5 to 30 minutes period When the module is connected measure the voltage again to make sure it did not decrease It is recommended to connect to the main power cable...

Page 11: ...short time Modem activity Off Device is not working or Device is in boot mode Characteristics Basic characteristics Table 5 Basic characteristics MODULE Name Quectel BG96 Teltonika TM2500 Technology L...

Page 12: ...0 C to 85 C Storage temperature without battery 40 C to 85 C Operating humidity 5 to 95 non condensing Ingress Protection Rating IP41 Battery charge temperature 0 C to 45 C Battery discharge temperatu...

Page 13: ...hold DIN3 2 5 V ANALOG INPUT Input voltage Recommended Operating Conditions Range 1 0 10 V Input resistance Range 1 38 45 k Measurement error on 12V Range 1 0 9 Additional error on 12 V Range 1 108 mV...

Page 14: ...ess which is inaccessible to the operator All related devices must meet the requirements of EN 60950 1 standard The device FMM130 is not designed as a navigational device for boats Do not disassemble...

Page 15: ...is necessary to read the User s Manual before your start using the device Full User s Manual version can be found in our Wiki This sign on the package means that all used electronic and electric equip...

Page 16: ...product Replaced with an equivalent repaired product fulfilling the same functionality TELTONIKA can also repair products that are out of warranty at an agreed cost Warranty Disclaimer TELTONIKA PRODU...

Reviews: