Mounting recommendations 

 

Connecting wires  

 

Wires should be connected while the module is not plugged in. 

 

Wires should be fastened to stable wires or other non-moving 
parts. Any heat emitting and/or moving objects should be kept 
away from the wires. 

 

There should be no exposed wires. If factory isolation was 
removed while connecting the wires, the isolation material 
should be applied. 

 

If the wires are placed in the exterior or in places where they 
can be damaged or exposed to heat, humidity, dirt, etc., 
additional isolation should be applied and the wires should not 
be loose. 

 

Wires cannot be connected to the board computers or control 
units. 
 

 

Connecting power source 

 

Be sure that after the car computer goes to sleep mode, power 
might be still available on the power wires. Depending on the 
car model, this may happen in 5 to 30 minutes period. 

 

When the module is connected, measure the voltage again to 
make sure it did not decrease. 

 

It is recommended to connect to the main power cable in the 
fuse box. 

 

3 A, 125 V external fuse shall be used. 
 

 

Connecting ignition wire 

 

Be sure to check if it is a real ignition wire i. e. power does not 
disappear after starting the engine. 

 

Check if this is not an ACC wire (when key is in the first position, 
most of the vehicle electronics are available). 

 

Check if power is still available when you turn off any of vehicles 
devices. 

 

Ignition is connected to the ignition relay output. As alternative, 
any other relay, which has power output when ignition is on, 
may be chosen. 
 

 

Connecting ground wire 

 

Ground wire is connected to the vehicle frame or metal parts 
that are fixed to the frame. 

 

If the wire is fixed with the bolt, the loop must be connected to 
the end of the wire. 

 

For better contact scrub paint from the spot where loop is 
going to be connected. 

 

 

Summary of Contents for FMM130

Page 1: ...Quick Manual v1 5 Advanced CAT M1 GSM GNSS BLE terminal with flexible inputs configuration FMM130...

Page 2: ...t the battery 6 PC Connection Windows 7 How to install USB drivers Windows 7 Configuration Windows 7 Quick SMS configuration 9 Mounting recommendations 10 LED indications 11 Characteristics 11 Basic c...

Page 3: ...3 FMM130 Wiki Know your device Figure 1 FMM130 device view...

Page 4: ...DIN 2 N AIN 1 Digital input channel 2 Negative input ground sense Analog input channel 1 Input range 0 30 VDC 5 DIN 1 Digital input channel 1 6 INPUT 6 TX EXT LVCAN TX 7 GND Ground pin 10 30 V DC 8 D...

Page 5: ...5 FMM130 Wiki Figure 3 FMM130 Wiring scheme Wiring scheme 1 Automotive relay 1...

Page 6: ...d or read our Wiki how to enter it later in Teltonika Configurator Make sure that Micro SIM card cut off corner is pointing forward to slot 3 Connect battery as shown to device Position the battery in...

Page 7: ...r installation window 4 In the following window click Install button Setup will continue installing the driver and eventually the confirmation window will appear Click Finish to complete the setup Con...

Page 8: ...y 1 Load from device loads configuration from device 2 Save to device saves configuration to device 3 Load from file loads configuration from file 4 Save to file saves configuration to file 5 Update f...

Page 9: ...detected by accelerometer Ignition will be detected by vehicle power voltage between 13 2 30 V Device makes a record On Moving if one of these events happen 300 seconds passes Vehicle turns 10 degree...

Page 10: ...on the car model this may happen in 5 to 30 minutes period When the module is connected measure the voltage again to make sure it did not decrease It is recommended to connect to the main power cable...

Page 11: ...short time Modem activity Off Device is not working or Device is in boot mode Characteristics Basic characteristics Table 5 Basic characteristics MODULE Name Quectel BG96 Teltonika TM2500 Technology L...

Page 12: ...0 C to 85 C Storage temperature without battery 40 C to 85 C Operating humidity 5 to 95 non condensing Ingress Protection Rating IP41 Battery charge temperature 0 C to 45 C Battery discharge temperatu...

Page 13: ...hold DIN3 2 5 V ANALOG INPUT Input voltage Recommended Operating Conditions Range 1 0 10 V Input resistance Range 1 38 45 k Measurement error on 12V Range 1 0 9 Additional error on 12 V Range 1 108 mV...

Page 14: ...ess which is inaccessible to the operator All related devices must meet the requirements of EN 60950 1 standard The device FMM130 is not designed as a navigational device for boats Do not disassemble...

Page 15: ...is necessary to read the User s Manual before your start using the device Full User s Manual version can be found in our Wiki This sign on the package means that all used electronic and electric equip...

Page 16: ...product Replaced with an equivalent repaired product fulfilling the same functionality TELTONIKA can also repair products that are out of warranty at an agreed cost Warranty Disclaimer TELTONIKA PRODU...

Reviews: