80
value
value
value
parameters
type
0
65535
-
U16
8.6.17
Trip distance mode (ID=1283)
There are three Trip types to choose: Between records, continuous trip, continuous.
Between records – distance is counted separately for every record. Continuous trip – distance in
records is summed up for the trip duration. Continuous – Distance is counted despite the trip
end or ignition off state(trip value is saved to flash memory). For this feature I/O#10 ODOMETER
must be enabled. If I/O ODOMETER is enabled, and Continuous distance counting variable is set
to Continuous (value 1), TRIP distance is going to be counted continuously (from TRIP start to
TRIP stop) and shown as I/O ODOMETER value.
Parameter
ID
Value
0 –Between records
1 – Continuous trip
Trip distance mode
1283
2 – Continuous
8.6.18
Enable odometer value setting (ID=1284)
Enables entering the current value of the odometer.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
U8
8.6.19
Continuous odometer value (ID=1285)
Enters a current odometer value.
Minimum
value
Maximum
value
Recommend
ed value
Goes with (depends on)
parameters
Value
type
0
4294967295
-
U32
8.6.20
Remember iButton ID, while trip is detected(ID=1286)
This feature saves the iButton ID to flash memory and sends it with every record, while trip
is detected.
Minimum
value
Maximum
value
Default value
Goes with (depends on)
parameters
Value
type
0
1
0
U8
8.6.21
Geofencing
In this chapter it is explained how to get all parameters for the first Geofence zone (all ID
numbers are for the 1
st
zone). And at the end of the chapter (part 8.6.10) is presented a table
with the IDs of all the rest Geofence zones.
8.6.21.1
Frame border (ID=1020)
Geofence border thickness, measured in meters.
Minimum
Maximum
Recommended
Goes with (depends on)
Value
Downloaded from
www.Manualslib.com
manuals search engine