12
Output Supply Voltage 1-Wire:
Supply Voltage
3.3
3.6
V
Output inner resistance
7
Ω
Output current (U
out
> 3.0V)
30
mA
Short circuit current (U
out
= 0)
130
mA
2.4
Absolute Maximum Ratings
VALUE
CHARACTERISTIC DESCRIPTION
Min.
Typ.
Max.
Unit
Supply Voltage (Absolute Maximum Ratings)
-32
32
V
Drain-Source clamp threshold voltage (Absolute
Maximum Ratings),
(
I
drain
= 2mA
)
36
V
Digital Input Voltage (Absolute Maximum Ratings)
-32
32
V
Analog Input Voltage (Absolute Maximum Ratings)
-32
32
V
2.5
Technical Information about internal battery
FM3622 internal battery is used for detecting external voltage disconnection.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT
TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Battery Disposal instructions:
Battery should not be disposed of with general household waste.
Bring damaged or worn-out batteries to your local recycling center or dispose
them to battery recycle bin found in stores.
Internal back-up battery
Battery voltage V
Nominal capacity (mAh)
Power(Wh)
Charging
temperature
range (◦C)
Li-Polymer rechargeable
battery
3,7
170
0.64 - 0.66
0 – 45