Figure 99 GPRS Week Time configuration
Device checks if the time between last saved record and current time is equal or higher
than Time based acquire interval. If so, FM1010 saves record to memory. If not, FM1010 checks
if the distance from last record to current record is equal or higher than Distance based acquire
interval. If so, saves the record to memory. If not and speed is higher than 10km/h, then FM1010
checks if angle difference between last record and current record is equal or higher than Angle
based acquire value. If so, saves the record to memory. These checks are performed every
second.
Note: Keep in mind that FM1010 operates in
GMT:0
time zone, without
daylight saving.
FM1010 is able to collect records using three methods at the same time: time, distance and angle
based data acquisition:
Time based data acquiring (Min. period) – records are being acquired every time when defined
interval of time passes. Entering zero disables data acquisition depending on time.