Notes: 

 

 

 

 

Programming is only by tone dial DTMF. Dont forget set 
even external line at PBX. 

 

 

Changes  are  valid  after  hang  up  only  (finishing  of 
programming  mode).  It  is  very  important  especially  in 
acknowledge  character  changes-  till  hang  up  you  must 
use previous acknowledgement. 

 

 

 

After numbers dialing you must wait for confirming 
request , insert acknowledge character and wait for 
confirming  tone.  When  you  insert  acknowledge 
charater before wont be accepted

 
 

 

 

Switch  to  programming  mode  is  possible  even  in  busy 
tone. 

 
 

 
 
 
 
 
 
 
 
 

Summary of Contents for MiniGate A

Page 1: ...e mail info telsyco com tel fax 420 241 765 832 www telsyco com TELSYCO s r o Prostřední 627 14 141 00 Praha 4 G S M G A T E MiniGate A MiniGate A MiniGate A MiniGate A Installation guide V 1 0 ...

Page 2: ...en is saved in phonebook Call billing allows control exact call duration due tax pulses 12 16 kHz 1 pulse when outgoing call is picked up Beeps in minute period into the call allows easy identification of GSM call Integrated USB port with PC software allows you easy configuration as same as sending and receiving SMS messages via SMS mail sw or data transmission option Thanks of many Mini Gate feat...

Page 3: ... 2 INSTALLATION Power supply telephone line USB Mini USB cable Yellow button anntena ...

Page 4: ...e place for installation select up following point of view 1 distance from PBX possibility of GSM interferences to other PBX lines as same as lenght of line from Gate to PBX max 200m 2 main 230 V for power supply of Gate 3 Quality of GSM signal at the installation place of GSM Gate Quality of GSM signal The sound quality depends on BTS setting where you are connected by the Gate To find best place...

Page 5: ...cation off After cca 30 seconds the yellow LED start flashing up GSM signal strength via LED table When pick up connected analogue phone or call to Mini Gate from PBX the LED of analogue line lights up green LED In the phone is hearing dial tone of Mini Gate It is ready to use The most often problems during Blue Gate compact installation All LED is not lighting Problem in power supply Check connec...

Page 6: ...n analogue phone is quiet It interrupted conduction of analogue line or so much big resistance in current loop for example longer cabel between PBX and Mini Gate Tle yellow LED communication to GSM is flashing up signal strength as same as green LED lights up Tle PBX hold pick up line of GSM Gate By incoming call you can remove this issue In other cases check PBX manual The Mini Gate works but cal...

Page 7: ...ng of data transmission Then is going back to Voice mode calling The same is when you are calling over unit It is busy for data transmission The optional sw supply to unit for sending and receiving SMS messages is SMS mail It is working under Outlook Outlook Expres Opera etc And you can work with SMS as with normal e mails see manual for SMS mail It works in batches and allows programm communicati...

Page 8: ...ledgement Wait for confirming tone Follow programming tone again Finish programming by hang up a phone Example programming of new permitted fix numbers 02 to memory 09 Dial acknowledgement default is In phone you are hearing waiting tone ƒƒ ƒƒ ƒƒ ƒƒ Dial password default 0000 Waiting tone is changing to programming tone ƒ ƒ ƒ ƒ Dial 1902 Wait for tone of confirming request 3 short tones Confirm th...

Page 9: ...mory which you want erase and confim it 22 very important feature is acknowledge character setting Default is When is used for PBX features you can change it on 24 An analogue phones are not enable send which is very used in GSM In this case is possible to use combination 00 to send it to mobile phone 31 This feature identificated connection of Mini Gate to external line at some type of PBX ex Sie...

Page 10: ...ode It is very important especially in acknowledge character changes till hang up you must use previous acknowledgement After numbers dialing you must wait for confirming request insert acknowledge character and wait for confirming tone When you insert acknowledge charater before wont be accepted Switch to programming mode is possible even in busy tone ...

Page 11: ... after 00 dialling 0 2 5 n Signalization to the call short tone each minute n 0 tone is turn off n 1 tone is turn on 0 2 6 n Restriction of call duration n 0 without restriction n 1 call duration restricted at 10 minutes 0 2 7 n PIN n 0 start without PIN n 1 start with PIN 0 2 8 n Type of acceptable dial of telephone number n 0 tone and pulse dial is acceptable n 1 pulse dial is acceptable only n ...

Page 12: ... n Amplification of sound in outgoing direction 1 to 4 1 3 9 n CLIR feature switching OFF outgoing CLIP 31 n 0 OFF n 1 ON 0 7 1 x x y y Xx 00 No charging pulses Xx 12 12 kHz charging pulses Xx 16 16 kHz charging pulses Yy 00 1 pulse only at the moment of connection Yy 01 to 99 seconds Pulses each 01 up 99 seconds 0 0 7 3 n N 0 CLIP is switch OFF N 1 FSK CLIP Bell N 2 FSK CLIP BT N 3 DTMF CLIP 1 7 ...

Page 13: ...ne short tone repated with quick cadence Mini Gate waiting for password insert ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ Programming short tone with quick cadence í Programming mode of Mini Gate ƒ ƒ ƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒ Confirmation inquiry 3 short tones Inquiry to confirm inserted parametr ƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒ Confirmation tone long tone Parametr was saved correctly ƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒ Minute tone short tone with 1 minute peri...

Page 14: ...onnection mode Flashing in 2 sec period SIM is unreadable for example wrong PIN SIM not inserted etc Short lights off with period 2 sec GSM modul doesnt communicate to CPU 1 5 flashes with period 4 sec stand by mode Number of flashes signal strength Short flashes in period 2 sec Gate is not registrate to GSM network Quick flashing with different period GSM communication logging to net call data co...

Page 15: ...nalogue telephopne line telephone interface 2 wires telephone conector RJ 11 Impedance 600 Ω 20 Dial tone DTMF tt 30 ms Pulse 28 200 20 200ms Billing 12 16 kHz Start and end of connection Polarity reversal Supply conduction symetrical 24V Current loop max 38 mA Resistance of subscribers conduction max 500 Ω Ringing 55 Vef 50 Hz Signalization 425 Hz 20Hz CLIP FSK Bell BT DTMF GSM mobile network com...

Page 16: ...fter preprogrammed number of digits 1 19 Immediate dial sent up setting or Permitted direction 9 memories of 4 digits numbers Dial type setting CLIR CLIP Call billing tax pulses 12 16 kHz Reversal polarity start and end of call Roaming ON OFF Call duration control Time beeps in call GSM signal strength identification ...

Page 17: ...stered company address TELSYCO s r o Prostřední 627 14 141 00 Praha 4 Czech Republic VAT CZ28548302 Company is registered in the Commercial Register administered by the Municipal Court in Prague Section C Record 149478 TELSYCO s r o Office Kyjovská 1983 1 142 00 Praha 4 Czech Republic E mail info telsyco com Tel Fax 420 241 765 832 ...