Fig. 4-2
4.4
ELECTRIC CONNECTION.
The electric supply for the machine's remote control and electro-hydraulic components must come
directly from the tractors' 12 volt battery.
The electric wires from the battery must have an area measurement of min. 2,5 mm
2
.
Connection to other contacts on the tractor can cause risk of misfunctions, and is not to recommend.
To secure the electric system against short-circuits there is an 10A fuse on the plus-leader, near to
the battery pole.
BROWN LEADER GOES TO BATTERY PLUS POLE
BLUE LEADER GOES TO BATTERY MINUS POLE
REMOTE CONTROL.
The control unit should be attached to a suitable place in the tractor cab, next to the front loader's
operating lever if the machine is front mounted.
THE REMOTE CONTROL UNIT IS NOT SHOCK-PROOF. MAKE SURE THAT IT IS FASTENED
TO A SOFT PAD THAT SECURES A NON-VIBRATING FOUNDATION.
* Emergency stop: see chapter 2.1