MA365 • Rev. A2
67
Tellabs
®
6325 Edge Node
3 Reference Information
Rating information for
cables
The rating information for the cables for the Tellabs 6325 node are listed in the
following table. The temperatures are shown in
°
C.
Item number
Description
Wire
Rated
Flammability
class
AWG
mm
2
Current
Voltage
Temp
DC
DC
Min.
Max.
WK-500Z-02.6-01 3 pole Molex
mini-fit to open
ended
18
0.75
9
300
-40
70
IEC60332-1
WK-480X-03.0-01 Craft terminal
interface cable,
RJ-45 to RJ-45
26
0.15
1
100
-25
80
IEC60332-1 & 2
WK-506Y-xx.x-01 Ethernet inter-
face cable, STP,
straight, RJ-45 to
RJ-45
26
0.15
1
100
-25
80
IEC60332-1 & 2
WK-507Y-xx.x-01 Ethernet inter-
face cable, STP,
crossed, RJ-45 to
RJ-45
26
0.15
1
100
-25
80
IEC60332-1 & 2
WK-504Y-xx.x-01 RJ-45 to open
ended cable, 120
ohm
26
0.15
1
100
-25
80
IEC60332-1 & 2
WK-503Y-xx.x-01 MDR to open
ended cable, 120
ohm
26
0.15
1
100
-25
80
IEC60332-1 & 2
WK-502X-03.0-01 9 pole D-sub to
open ended, 120
ohm
26
0.15
1
100
-40
70
IEC60332-1
WK-501Y-03.0-01 RJ-45 to 15 pole
D-sub
26
0.15
/
0.75
1
100
-25/
-40
80/
70
IEC60332-1
WK-482B-xx.x-01 1.0/2.3 to 1.0/
2.3 coaxial cable
28
0.09
1
100
-20
70
IEC60332-1
WK-483B-xx.x-01 1.0/2.3 to BNC
coaxial cable
28
0.09
1
100
-20
70
IEC60332-1
WK-484B-xx.x-01 1.0/2.3 to 1.6/
5.6 coaxial cable
28
0.09
1
100
-20
70
IEC60332-1
WK-497B-20.0-01 1.0/2.3 to open
ended coaxial
cable
28
0.09
1
100
-20
70
IEC60332-1
WK-508B-01.0-01 RJ-45 to 1.0/2.3
(female) cable
with 120/75
ohm balun
26
0.15
1
100
-25
80
IEC60332-1