6
CONFIGURING THE DEVICE:
You can configure the device using commands sent by SMS to the phone
number of the SIM card installed in the device. It is possible to send multiple
commands (settings) in the same SMS, but the message must not exceed
140 characters! Each message must begin with the device password, using the
PWD=password#
command, and must end with the hash
#
character. Otherwise,
the device will reject the requests.
SMS COMMANDS
PWD=1111#
Providing the password
– necessary at the beginning
of each message! (Default password: 1111)
PWC=new password#
Changing the password. The password must consist of
4 alphanumeric non-
accented characters (A…z, 0...9)
TEL=phone number#
Adding a new user (phone number)
DEL=phone number#
Deleting a user (phone number)
REL1=X#
Output NO1 activation time: substitute parameter
X
with the time interval
– value between
1…1000
(sec)
or with parameter
FIX
for bistable mode (default: 1s)
REL2=X#
Output NO2 activation time: substitute parameter
X
with the time interval
– value between
1…1000
(sec)
or with parameter
FIX
for bistable mode (default: 1s)
INTYPE1=X#
Type of input IN1: substitute
X
with:
NO
=normally open
or
NC
=normally closed (default: NO)
INTYPE2=X#
Type of input IN2: substitute
X
with:
NO
=normally open
or
NC
=normally closed (default: NO)
IN1=X#
Sensitivity of input IN1: substitute parameter
X
with the
needed sensitivity
– value between
1…1000
(seconds)
(default: 1s)
IN2=X#
Sensitivity of input IN2: substitute parameter
X
with the
needed sensitivity
– value between
1…1000
(seconds)
(default: 1s)
REPORT=phone
number#
Adding a phone number where the device will send
and forward SMS messages
REPORT=#
Deleting the SMS sending/forwarding phone number
SMSLIMIT=X#
SMS limitation per input: substitute
X
with the desired
setting: value between
1…50
(pcs). To disable the
limitation, substitute
X
with
0
. (default: 1)
TEL?#
Requesting registered phone numbers
STATUS?#
Requesting module status