GE865 Hardware User Guide
1vv0300799 Rev.9 – 27-07-2009
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 21 of 70
5.2.1 Hardware shutdown
To turn OFF the GE865 the pad ON# must be tied low for at least 2 seconds and then
released.
The same circuitry and timing for the power on shall be used.
The device shuts down after the release of the ON# pad.
TIP:
To check if the device has powered off, the hardware line PWRMON should be
monitored. When PWRMON goes low, the device has powered off.