Picotrack 4G User Manual V1.2
Seite 18
Afterwards, you can check the flashing behaviour, Mobile LED should flash once, when the device is
logged into the mobile network, and twice when an IP connection to the server is established.
More detailed information can be found in the „Status Indicators“ chapter of this manual.
A lot of parameters can be configured in order to implement the proper use case.
Besides, the unit has to be configured in order to forward messages (events) to the proper server; in
the following paragraphs some scenarios will be illustrated as examples (all the details can be found in
the Software Protocol Specification, basic and expert type).
Tracking – typical configuration profiles
Pedestrian & Vehicle Live (1min interval)
Position messages are generated every 60 seconds when in motion, regardless of speed or
changes of driving direction.
This means that a position message is generated and transmitted every 2 km on a freeway or
highway (driving with about 120km/h).
As soon as motion is ended (detected by built-in sensor), the device will go to sleep mode. When
going back to motion (detected by the sensor), the device will automatically resume tracking.
A routine event (“I am alive”) will be sent once a day.
Then the power mode will be motion-sleep mode (
5
), and time interval
60
sec.
The following extra messages are generated and sent to the server (value=
2
in the 32 bytes
sequence detailed below):
Power Supply connected / disconnected
Ignition signal on / off
Digital Input 2 signal on / off
Digital Input 4 signal on / off
Device stopped moving (
30
seconds without any sensor motion detection)
Device started moving (according motion sensitivity level
3
)
Periodic Wakeup / Routine message (every
24
hours)
Configuration SMS :
0011{6digitsIMEI},,,,
60
,0,200000700000,
5
0000009,000000000
2222222
00000000
22
000000,,,,,,0,0,0
,0,
24
,,,,
3
,
30
,,,,30,6
Configuration command through serial line:
CONFIG=,,,,60,0,200000700000,50000009,00000000022222220000000022000000,,,,,,0,0,0,0,24,,,,3,
30,,,,30,6
Remark: the “0011{6digitsIMEI}” of the SMS becomes “CONFIG=” in the serial command; the rest
remains unchanged.