background image

Installation

14

FIGURE 8.

Intermediate Power Configuration for Channels 3-6 (or 7-10, 11-14, etc.)

. This power supply 

configuration should only be used at one point in each group of 4 channels. Typically, it is set up at the central master 
station. It permits about twice as many remote stations on the 4 channels than is possible with the power supply 
configuration shown in Figure 6.

CHN 1

CHN 2

CLASS 2 WIRING 1.5A 24VDC

100-249 VAC 60/50 HZ

MADE IN USA

®

CHN 1

CHN 2

CLASS 2 WIRING 1.5A 24VDC

100-249 VAC 60/50 HZ

MADE IN USA

®

XP-ES4000

12-15 VDC

+

-

3

SPEAKERS

PROGRAM

INPUTS

4

LINE LEVEL

1 VRMS

EXP

OUT

CAN 3-6 OUTPUTS

EXP

IN

5

6

3

4

5

6

PGM VOLUME

BAL-OUT

UNBAL-IN

Telex

®

FRONT

BACK

CH 3-6

ES4000A

PUSH

PUSH

PUSH

PUSH

PS2000L Power Supplies

Combine / Isolate switches set to Isolate

TO REMOTE MASTER
STATIONS AND BELT PACKS

TO US2000A

EXP IN CONNECTOR

TO THE EXP IN CONNECTOR

OF ANOTHER ES4000A

CH 6

CH 5

CH 4

CH 3

1

1

1

1

1

1

1

CH 3

CH 6

CH 5

CH 4

1

11

5

5

NOTE

: For 

further 
information 
about cable 
numbers, see 
“Cables” on 
page 20

Summary of Contents for Audiocom ES4000A

Page 1: ...Talk Listen Call Talk Listen Call Talk Listen Call Talk Listen Call 3 4 5 6 ES4000A ES4000A Intercom Expansion Station User Instructions 9350 7551 000 Rev C 04 2006...

Page 2: ...made via UPS Ground prepaid you may request from Factory Service a different shipment method Any shipment upgrades will be paid by the customer The equipment should be shipped in the original packing...

Page 3: ...5 Audiocom Call Send and Receive DIP Switches 7 Balanced Unbalance Switch SW2 7 Direct Program Listen Enable Disable Jumpers 7 Sidetone Trimmers 7 Mounting Configurations 7 Connection Notes 11 Cables...

Page 4: ......

Page 5: ...eaker outputs for independent monitoring of one or more of the 4 channels if desired The US2000A ES4000A combination can be used as a simple multi channel intercom user station In this configuration t...

Page 6: ...uirements and call signaling requirements 8 Program Inputs Connector and Trimmers Each intercom channel has its own program input and level adjustment trimmer For each program input there is an intern...

Page 7: ...d 3 screws from each side DIP Switches DIP switches and their default settings are listed in Table 1 on page 6 The following paragraphs provide additional details Program Interrupt DIP Switches Each I...

Page 8: ...io Call Send Ch 3a ON Closed Enabled OFF Open Disable ON SW1 7 Audio Call Send Ch 4a ON Closed Enabled OFF Open Disable ON SW1 8 Audio Call Send Ch 4a ON Closed Enabled OFF Open Disable ON Push button...

Page 9: ...jack on the back of the ES4000A To disable direct program listening for a program input reset the appropriate jumper as show in Table 2 Locations of the jumpers are shown in Figure 2 on page 4 Sideto...

Page 10: ...rack wide components SPK 1000 RMK S Single Unit Rack Mount Kit for one 1 2 rack wide Audiocom component RMK D Dual Unit Rack Mount Kit for two 1 2 rack wide Audiocom components RMK M Multi Unit Rack M...

Page 11: ...an ES4000A Connections and further details for this configuration are shown in Figure 6 NOTE An additional rack mount space is shown between the two PS4000 power supplies This may be required to prev...

Page 12: ...re 6 The power supply connections for the US2000A are shown in Figure 7 the power supply connections for the ES40000A are shown in Figure NOTE Additional rack spaces are shown between the rows of powe...

Page 13: ...cks IMPORTANT The PS L power supply only provides power for the station that it is connected to You cannot use the PS L to power the intercom channels Never connect more than 1 SPS2000A PS2000L or PS4...

Page 14: ...NECT TO ES 4000 CLASS 2 WIRING 2A 24VDC CH 7 10 PS4000 ES4000A 12 15 VDC 3 SPEAKERS PROGRAM INPUTS 4 LINE LEVEL 1 VRMS EXP OUT CAN 3 6 OUTPUTS EXP IN 5 6 3 4 5 6 PGM VOLUME BAL OUT UNBAL IN Telex CHN...

Page 15: ...HZ MADE IN USA PS2000L Channel 2 Power Combine Isolate Switch set to Combine CHN 1 CHN 2 100 240 VAC 60 50 HZ MADE IN USA INPUT 1 SPEAKER INPUT 2 LINE LEVEL 1 VRMS 12 15 VDC 1 SPEAKERS PROGRAM INPUTS...

Page 16: ...24VDC 100 249 VAC 60 50 HZ MADE IN USA CHN 1 CHN 2 CLASS 2 WIRING 1 5A 24VDC 100 249 VAC 60 50 HZ MADE IN USA XP ES4000 12 15 VDC 3 SPEAKERS PROGRAM INPUTS 4 LINE LEVEL 1 VRMS EXP OUT CAN 3 6 OUTPUTS...

Page 17: ...FRONT BACK CH 3 6 ES4000A PUSH PUSH PUSH PUSH PS2000L Power Supplies Combine Isolate Switches set to Combine CHN 1 CHN 2 CLASS 2 WIRING 1 5A 24VDC 100 249 VAC 60 50 HZ MADE IN USA CHN 1 CHN 2 CLASS 2...

Page 18: ...OUTPUTS EXP IN 5 6 3 4 5 6 PGM VOLUME BAL OUT UNBAL IN Telex FRONT BACK CH 3 6 ES4000A PUSH PUSH PUSH PUSH CHN 1 CHN 2 CLASS 2 WIRING 1 5A 24VDC 100 249 VAC 60 50 HZ MADE IN USA CHN 1 CHN 2 CLASS 2 WI...

Page 19: ...KERS PROGRAM INPUTS 4 LINE LEVEL 1 VRMS EXP OUT CAN 3 6 OUTPUTS EXP IN 5 6 3 4 5 6 PGM VOLUME BAL OUT UNBAL IN Telex FRONT BACK PUSH PUSH PUSH PUSH FROM MASTER STATION OR BELT PACK FROM MASTER STATION...

Page 20: ...NPUTS 4 LINE LEVEL 1 VRMS EXP OUT CAN 3 6 OUTPUTS EXP IN 5 6 3 4 5 6 PGM VOLUME BAL OUT UNBAL IN Telex FRONT BACK CH 3 6 ES4000A PUSH PUSH PUSH PUSH PS2000L Power Supplies Combine Isolate Switches set...

Page 21: ...LINE LEVEL 1 VRMS EXP OUT CAN 3 6 OUTPUTS EXP IN 5 6 3 4 5 6 PGM VOLUME BAL OUT UNBAL IN Telex FRONT BACK CH 3 6 ES4000A PUSH PUSH PUSH PUSH CH 1 CH 2 CH 6 CH 5 CH 4 CH 3 INPUT1 INPUT2 12 15 VDC BAL 1...

Page 22: ...aker cable with RCA plugs One supplied with each SPS2000A SPK 1000 and SPK 2000 5 18 457mm CHANNEL OUTPUT cable stereo miniplug to stereo miniplug One supplied with each ES4000A 6 18 457mm CHANNEL OUT...

Page 23: ...itchcraft Pin 1 Common Pin 2 Shield Standard cables are generally constructed using a male connector at one end and a female connector at the other end This allows several cables to be interconnected...

Page 24: ...Installation 22...

Page 25: ...tment procedure as described in the US2000A User Instructions except substitute channel 3 channel 4 etc The locations of the ES4000A sidetone trimmers are shown in Figure 15 Operation The ES4000A chan...

Page 26: ...L switch set to BAL position Output Level 1VRMS nominal Input Impedance 300 ohms Bridging Impedance greater than 10 000 ohms Sidetone 40dB 35dB adjustable range Call Signalling Send 20kHz 100Hz 0 47VR...

Page 27: ...EL 3 6 OUTPUTS Connector Connector Type DB15F Female 15 pin D sub Pin 1 Channel 3 intercom audio input output high Pin 2 Channel 3 intercom audio input output low Pin 3 Common Pin 4 Channel 5 intercom...

Page 28: ...b One supplied with each ES4000A Pages 16 21 All cables labeled with number 6 should be labeled with number 11 The description for cable number is 11 is 18 457mm CHANNEL OUTPUT cable 15 pin Male Dsub...

Page 29: ...27 Addendum Errata Sheet...

Page 30: ......

Reviews: