13
Connection Notes
FIGURE 7.
Maximum Power Configuration for Channels 1 and 2.
This power supply configuration should only be
used at one point in channels 1 and 2. Typically, it is set up at the central master station. This configuration permits about
twice as many remote stations on channels 1 and 2 than the configuration shown in Figure 6 on page 12.
NOTE
: A
PS2000L may be substituted for the SPS2000A for headset-only operation.
CHN 1
CHN 2
100-249 VAC 60/50 HZ
MADE IN USA
®
PS2000L
Channel 2 Power
Combine / Isolate Switch
set to Combine
CHN 1
CHN 2
100-240 VAC 60/50 HZ
MADE IN USA
®
INPUT 1
SPEAKER
INPUT 2
LINE LEVEL
1 VRMS
12-15 VDC
+
-
1
SPEAKERS
PROGRAM
INPUTS
2
LINE LEVEL
1 VRMS
P.A.
EXP
OUT
CHN 2
VOL
PGM 2
VOL
PGM 1
BAL - OUT
UNBAL - IN
PUSH
PUSH
CHN 1
To ½ of stations
on channel 2
To ½ of stations
on channel 1
To ½ of stations
on channel 2
To ½ of stations
on channel 1
SPS2000A
Channel 1 Power and
All-Channel Speaker
Combine / Isolate Switch
set to Combine
Note:
US2000A Internal
DIP switches set
for monaural
operation (default)
1
1
1
1
1
1
4
PS-L
(Optional)
NOTE
: For further
information about
cable numbers, see
“Cables” on page 20
Summary of Contents for Audiocom ES4000A
Page 4: ......
Page 24: ...Installation 22...
Page 29: ...27 Addendum Errata Sheet...
Page 30: ......