Televes OSSGT Operating Instructions Manual Download Page 7

7

EN

3. Keyboard

The keyboard operation will depend on the current 
working mode. See the table below:

Button

Main functions

Swith On / Swithc Off  the device (press and hold).

Change the view diplayed on the screen (X/Y).

Perform a test arc or re-arc.

Access menu, sub-menus and saves parameters.

Oven start-up.

Exit the menu and get the engines back to their 

initial position.

Perform splicing (when fi bers are positioned).

Next.

Back.

More.

Less.

4. Start-up and menu description

To switch the fusion splicer on or off , press and hold the

key  

 .

Once switched on, press  

  to access the “Main Menu”.

Once there, the diff erent modes of the splicer will be 
accessible.

Options

Description

Function 

Setting

Fast adjustments related with the use of the 

device.

Splice Mode

Allows the selection of the fi ber type and the 

work mode.

Heating Mode

Allows the selection of the heat-shrink 

protector type.

History Records

Displays the splice date and the images 

recorded.

Maintenace

Menu for use-based maintenance.

Sistema

System confi 

guration: language, screen, 

power, ...

4.1 Function Setting

In this option, the parameters shown below will be 

confi gurable:

            

              

Parameter

Description

Quick ARC 

Calibration 

Mode

With this option activated, a quick calibration 

arc will be performed before the splicing 

process begins.

Tension test

With this option activated, a tension test of 2N 

will be performed after the splicing process 

has ended to check the splice’s resistance.

Motor reset 

waiting time

Waiting time for the engines to go back to 

initial position once raised the cover after the 

splicing process is completed.

Automatic 

splice

With this option activated, the splicing process 

will begin once the cover is closed, without the 

help of any key.

Automatic 

heating

With this option activated, the heating process 

will begin once the cover is closed, without the 

help of any key.

Force heat

With this option activated, the device will force 

the heating process in case this one does not 

begin.

Auto save splice 

image

With this option activated, the images with the 

results of the last 20 splices performed will be 

automatically saved.

Summary of Contents for OSSGT

Page 1: ...Electric arc fusion splicer Ref 232105 OSSGT Operating instructions w w w t e l e v e s c o m EN Ref 23...

Page 2: ......

Page 3: ...ection 10 4 5 6 USB Mode 10 4 6 System Setting 10 4 6 1 ECO Mode 11 5 Splice process 11 5 1 Electrode and element inspection 11 5 2 Fiber preparation 11 5 3 Fiber type 12 5 4 Fiber introduction into t...

Page 4: ...by falling o crashing You must switch off the equipment and immediately remove the battery Then contact the Technical Support department of Telev s to proceed with its inspection or repair 3 Internal...

Page 5: ...the spliced fiber and to the calculation of optical loss it helps the operator ensure the fusion was performed correctly Thanks to its battery interchangeable from the outside it allows working in pl...

Page 6: ...r Front view Side views Fiber clamps Camara lens x2 Electrode x2 V Groove x2 Keyboard 2 Heater Keyboard 1 LCD screen Lashing eyelet Lashing eyelet Battery indicator push button Power supply connector...

Page 7: ...nace Menu for use based maintenance Sistema System configuration language screen power 4 1 Function Setting In this option the parameters shown below will be configurable Parameter Description Quick A...

Page 8: ...ows the modification of the enhanced duration of the arc usual value 1000ms It can be increased in case that after splicing there is narrowing detected on the fiber at the splicing spot If the fiber i...

Page 9: ...displayed Delete records Erases all the records that the device has registered Query fault records Displays the records of all the failed splices Delete fault records Erases all the records of the fa...

Page 10: ...be displayed on the screen The PC will show a new disc unit containing the folders below For downloading the records you must access the folder RECORD within the same SPLICE TXT is the file that cont...

Page 11: ...rrors Check the correct alignment of the electrodes and make sure their ends are in good shape Should you find any impurities take them away with a wipe swab dampened with isopropyl alcohol 5 2 Fiber...

Page 12: ...usly entered the Start menu with the Menu key The fusion splicer will not work unless you are on that menu Check the fibers hanging from the fusion splicer are not blocked by the cover or held by the...

Page 13: ...g a 45o angle with each other Note Apply a controlled force for the cleaning of the V groove It is a sensitive precision element 6 2 Cameras or lenses Clean the lenses regularly Presence of dirt on th...

Page 14: ...ting blade and by the means of a screwdriver pull out the screw 3 Replace the cutting blade and re assemble following the steps descrived above in reverse order 6 6 Stripper You should occasionally lu...

Page 15: ...Y axis 180x magnification X axis or Y axis separately 360 magnification Screen 4 3 high performance LCD Tensile test 2N standar Heat shrink protectors 60 50 45 40 30 and 25mm Electrode duration 3 000...

Page 16: ...www televes com...