ELECTRIC-ARC FUSION SPLICER

Important safety instructions

General conditions for installation

1 .  

 

Read this manual before operating or connecting the 
equipment.  

2 . Keep these operating instructions in a safe place.
3 . Pay attention to all the warnings. 
4 . Follow all instructions. 
5 . Do not use this equipment near water.
6 . Clean the outside with a dry cloth only.

 

Only use attachments/accessories specifi 

ed by the 

manufacturer.

8 .    Do not step on or pinch the network cable of the power supply 

unit; pay special attention to plugs, power connections, and 
the spots where they leave the equipment.

9 .  Refer all servicing to qualifi ed service personnel. Servicing is 

required when the apparatus has been damaged in any way, 
such as power-supply cord or plug is damaged, liquid has 
been spilled or objects have fallen into the apparatus, the 
apparatus has been exposed to rain or moisture, does not 
operate normally, or has been dropped .

Warning

    Equipment shall not be immersed in any kind of liquid. It is 

recommended to avoid placing the device next too objects 
fi lled with liquids, such as glasses.

  Ambient temperature should not be higher than 50 °C .
   Do not place the equipment near heat sources or in a highly 

humid environment .

   Do not place the equipment in a place where it can suff er 

vibrations or shocks .

  Please allow air circulation around the equipment .
   Do not place naked fl ames, such as lighted candles on or near 

the product.

How to charge the equipment safely

    Power requirements for the power supply unit should be: 100- 

240V~ 50/60Hz.

    To disconnect the power supply from the mains pull the plug 

never the cable.

    It is strongly recommended not to connect the power supply 

unit to the mains until all connections have been done.

    Reduce the risk of fi re or electric shock, do not expose this 

power supply unit to rain or moisture.

Fusion splicer precautions

1

  The charging voltage of this fusion splicer is limited .

     Always use the power supply unit provided with the equipment 

to charge the internal battery .

2

  Should the fusion splicer show any of the following anomalies 

at some point:

               - Weird smoke, smell or noise.
               - Extreme heat.
               - Weird liquid or matter inside the equipment.
               - Breakdown or damage caused by falling o crashing.
      You must switch off  the equipment and immediately remove 

the battery. Then, contact the Technical Support department 
of Televés to proceed with its inspection or repair.

3  

Internal manipulation of the fusion splicer involves losing the 
product warranty (do not take the equipment apart).

4  

Any errors in the equipment’s external maintenance could 
damage the fusion splicer or result in injury to the operator 
(carefully follow the maintenance instructions).

5  

Never use the fusion splicer in the presence of fl ammable 
gases or liquids. Otherwise, it may lead to fi res, explosions or 
other serious consequences.

6  

This fusion splicer is only used for optical fi bre fusion, and 
should not be used for any other purposes.

7  

Do not expose the fusion splicer to high temperature or 
humidity.

8  

Avoid working in environments that are dusty or contain 
airborne particles. This situation may cause failure in the fusion 
operations or damage to the equipment.

9  

Using the fusion splicer under diff erent climatic conditions 
(going from a cold to a warm environment, for instance) 
may generate condensation in the equipment. Wait for the 
condensation to completely disappear before working with it.

10  

To keep the appropriate performance of the fusion splicer 
(based on the use that is made of it) we recommend cleaning 
the equipment periodically.

11  

The fusion splicer is calibrated infactory. Avoid strong 
vibrations or impacts, and use its own case for transport and 
storage.

12  

Due to the high complexity of this equipment, it should only 
be repaired by Televés.

Notes

    Be aware that ignoring these warnings or using the fusion 

splicer inappropriately may result in serious injuries: please 
follow the recommended safety standards for this equipment.

  Always use safety goggles when working with optical fi bre.

Symbology 

  

                          The power supply unit is designed for indoor use.

                                      

  The power supply unit meets the safety requirements 

for class II equipment.

                              The  equipmentcan  not  be  treated  as  regular 

house hold waste,and should be handed over to 
the appropriate collection point for waste electrical 
and electronics equipment (WEEE).

                         

  

 

 

The equipment includes a recyclable battery; 
prior to handing it over at the WEEE collection 
premises, the battery should be removed from 
the equipment and separately delivered for 
appropriate management.

                            
 

 

 

 The equipment complies with the CE mark 
requirements.

Summary of Contents for OSSGT

Page 1: ...Electric arc fusion splicer Ref 232105 OSSGT Operating instructions w w w t e l e v e s c o m EN Ref 23...

Page 2: ......

Page 3: ...ection 10 4 5 6 USB Mode 10 4 6 System Setting 10 4 6 1 ECO Mode 11 5 Splice process 11 5 1 Electrode and element inspection 11 5 2 Fiber preparation 11 5 3 Fiber type 12 5 4 Fiber introduction into t...

Page 4: ...by falling o crashing You must switch off the equipment and immediately remove the battery Then contact the Technical Support department of Telev s to proceed with its inspection or repair 3 Internal...

Page 5: ...the spliced fiber and to the calculation of optical loss it helps the operator ensure the fusion was performed correctly Thanks to its battery interchangeable from the outside it allows working in pl...

Page 6: ...r Front view Side views Fiber clamps Camara lens x2 Electrode x2 V Groove x2 Keyboard 2 Heater Keyboard 1 LCD screen Lashing eyelet Lashing eyelet Battery indicator push button Power supply connector...

Page 7: ...nace Menu for use based maintenance Sistema System configuration language screen power 4 1 Function Setting In this option the parameters shown below will be configurable Parameter Description Quick A...

Page 8: ...ows the modification of the enhanced duration of the arc usual value 1000ms It can be increased in case that after splicing there is narrowing detected on the fiber at the splicing spot If the fiber i...

Page 9: ...displayed Delete records Erases all the records that the device has registered Query fault records Displays the records of all the failed splices Delete fault records Erases all the records of the fa...

Page 10: ...be displayed on the screen The PC will show a new disc unit containing the folders below For downloading the records you must access the folder RECORD within the same SPLICE TXT is the file that cont...

Page 11: ...rrors Check the correct alignment of the electrodes and make sure their ends are in good shape Should you find any impurities take them away with a wipe swab dampened with isopropyl alcohol 5 2 Fiber...

Page 12: ...usly entered the Start menu with the Menu key The fusion splicer will not work unless you are on that menu Check the fibers hanging from the fusion splicer are not blocked by the cover or held by the...

Page 13: ...g a 45o angle with each other Note Apply a controlled force for the cleaning of the V groove It is a sensitive precision element 6 2 Cameras or lenses Clean the lenses regularly Presence of dirt on th...

Page 14: ...ting blade and by the means of a screwdriver pull out the screw 3 Replace the cutting blade and re assemble following the steps descrived above in reverse order 6 6 Stripper You should occasionally lu...

Page 15: ...Y axis 180x magnification X axis or Y axis separately 360 magnification Screen 4 3 high performance LCD Tensile test 2N standar Heat shrink protectors 60 50 45 40 30 and 25mm Electrode duration 3 000...

Page 16: ...www televes com...

Reviews: