protection along the fi ber until it fully covers the splice 
area. The process fi nal step will be to introduce this heat-
shrink protector into the “HEATER” of the equipment by 
pressing the “HEAT” key, as long as the automatic heating 
option is not activated.

Bear in mind that while the heater’s red LED is on, the 
heater is near its maximum operating temperature. 
When this LED turns off  (a beep will be produced), the 
temperature will have reached its maximum  value,  but 
the process will still be on-going. Wait until you hear 
a second beep (indicating the oven has reached its 
minimum temperature), to take the tube out of the heater 
and place it on the cooler tray.
It is likely that the equipment’s internal fans turn on while 
the heater is being used .
This process manages the temperature of the heater’s 
components to enhance durability .

6. Maintenance

6.1 V-groove

Clean the V-groove.
In most cases, splice fusion high losses are caused by 
the presence of contamination (residues/dirt) on the 
V-groove. Therefore, you will need to clean both by 
following the steps below:

1

  Open the protective cover .

2

  Clean the V-grooves using specifi c cleaning swabs (Ref . 

232710), dampened with isopropyl alcohol .

3

  

Should the dirt be adhered, you can use a stripped clean 
fi bre to push it out (put the fi ber and V-groove forming a 
45o angle with each other) . 

Note: 

Apply  a  controlled  force  for  the  cleaning  of  the           

V- groove. It is a sensitive precision element.

                            

6.2 Cameras or lenses

Clean the lenses regularly.
Presence of dirt on the lenses will result in splicing fusion 
problems. Therefore, you should periodically inspect the 

lenses and clean them if necessary, by following the steps 
below:

Open the protective cover.

Clean both lenses using a specifi c swab (Ref. 232710) 
dampened with isopropyl alcohol, by drawing circles 
progressively increasing in diameter (start from the 
center outwards) .

3

  Use a dry swab to get rid of possible residues and have 

the lenses fully dried .

4  

Make sure no residues are left on the surface of the 
lenses after cleaning .

Note:

 During the cleaning, be careful not to push or hit 

the electrodes . Apply a controlled force (lenses are very 
sensitive elements). Excessive pressure could result in 
scratches, that would make the lenses unusable. 

                            

6.3 Changing the cleaver’s cutting blade 
position

The cleaver’s cutting blade has 23 positions. Each position 
can execute 1,000 cutting operations, which means 23,000 
cuts per blade.

                             

As long as the cleaver operates correctly, do not modify 
the blade’s position, even if more than 1,000 cuts have 
been performed. You should only modify the blade’s 
position if you observe that despite its height being 
correct, the blade is not able to cut.

Follow the steps below to modify the blade’s position:

1

  Remove the fi bers deposit loosening the screw indicated 

in the picture below:

Summary of Contents for OSSGT

Page 1: ...Electric arc fusion splicer Ref 232105 OSSGT Operating instructions w w w t e l e v e s c o m EN Ref 23...

Page 2: ......

Page 3: ...ection 10 4 5 6 USB Mode 10 4 6 System Setting 10 4 6 1 ECO Mode 11 5 Splice process 11 5 1 Electrode and element inspection 11 5 2 Fiber preparation 11 5 3 Fiber type 12 5 4 Fiber introduction into t...

Page 4: ...by falling o crashing You must switch off the equipment and immediately remove the battery Then contact the Technical Support department of Telev s to proceed with its inspection or repair 3 Internal...

Page 5: ...the spliced fiber and to the calculation of optical loss it helps the operator ensure the fusion was performed correctly Thanks to its battery interchangeable from the outside it allows working in pl...

Page 6: ...r Front view Side views Fiber clamps Camara lens x2 Electrode x2 V Groove x2 Keyboard 2 Heater Keyboard 1 LCD screen Lashing eyelet Lashing eyelet Battery indicator push button Power supply connector...

Page 7: ...nace Menu for use based maintenance Sistema System configuration language screen power 4 1 Function Setting In this option the parameters shown below will be configurable Parameter Description Quick A...

Page 8: ...ows the modification of the enhanced duration of the arc usual value 1000ms It can be increased in case that after splicing there is narrowing detected on the fiber at the splicing spot If the fiber i...

Page 9: ...displayed Delete records Erases all the records that the device has registered Query fault records Displays the records of all the failed splices Delete fault records Erases all the records of the fa...

Page 10: ...be displayed on the screen The PC will show a new disc unit containing the folders below For downloading the records you must access the folder RECORD within the same SPLICE TXT is the file that cont...

Page 11: ...rrors Check the correct alignment of the electrodes and make sure their ends are in good shape Should you find any impurities take them away with a wipe swab dampened with isopropyl alcohol 5 2 Fiber...

Page 12: ...usly entered the Start menu with the Menu key The fusion splicer will not work unless you are on that menu Check the fibers hanging from the fusion splicer are not blocked by the cover or held by the...

Page 13: ...g a 45o angle with each other Note Apply a controlled force for the cleaning of the V groove It is a sensitive precision element 6 2 Cameras or lenses Clean the lenses regularly Presence of dirt on th...

Page 14: ...ting blade and by the means of a screwdriver pull out the screw 3 Replace the cutting blade and re assemble following the steps descrived above in reverse order 6 6 Stripper You should occasionally lu...

Page 15: ...Y axis 180x magnification X axis or Y axis separately 360 magnification Screen 4 3 high performance LCD Tensile test 2N standar Heat shrink protectors 60 50 45 40 30 and 25mm Electrode duration 3 000...

Page 16: ...www televes com...

Reviews: