Televes OSSGT Operating Instructions Manual Download Page 10

10

ELECTRIC-ARC FUSION SPLICER

4.5.2 Clean electrodes

Press the “Menu” key and follow the steps displayed on the 
device:

  

           

4.5.3 Replace electrodes

Press the “Menu” key and follow the steps displayed on the 
device:

           

4.5.4 Self-Diagnosis Test:

Press the “Menu” key and follow the steps displayed on the 
device:

           

4.5.5 Optical correction

Press the “Menu” key and follow the steps displayed on the 
device:

       
           

4.5.6 USB Mode

Connect the USB cable, included with the splicer, to the PC 
to access this mode.
Once connected, you can proceed to do the following 
options:
           - Update the software of the device.
           - Download the records of the unit.
When connected to PC, the following message will be 

displayed on the screen:

           

The PC will show a new disc unit containing the folders 
below:

                                    

For downloading the records, you must access the folder 
“RECORD”, within the same, “SPLICE.TXT” is the fi le  that 
contains the records of the splices correctly performed, 
while, “ERROR.TXT”, contains the failed records.

 

                   

To update the software version of the unit, you simply 
have to introduce the update fi le in the root folder of the 
device, just as shown below:

                                           

Once the fi le is introduced, unplug the device and reboot 
the splicer so the update process is able to begin, when 
switched on again a progress bar regarding to the 
installation of the update will be displayed.

To confi rm that the update has been successfully installed, 
access to 

Main Menu

 

 

System Setting

 

Version

.

4.6 System Setting

In this section, the parameters regarding to the main use 
of the device can be modifi ed.

            

Summary of Contents for OSSGT

Page 1: ...Electric arc fusion splicer Ref 232105 OSSGT Operating instructions w w w t e l e v e s c o m EN Ref 23...

Page 2: ......

Page 3: ...ection 10 4 5 6 USB Mode 10 4 6 System Setting 10 4 6 1 ECO Mode 11 5 Splice process 11 5 1 Electrode and element inspection 11 5 2 Fiber preparation 11 5 3 Fiber type 12 5 4 Fiber introduction into t...

Page 4: ...by falling o crashing You must switch off the equipment and immediately remove the battery Then contact the Technical Support department of Telev s to proceed with its inspection or repair 3 Internal...

Page 5: ...the spliced fiber and to the calculation of optical loss it helps the operator ensure the fusion was performed correctly Thanks to its battery interchangeable from the outside it allows working in pl...

Page 6: ...r Front view Side views Fiber clamps Camara lens x2 Electrode x2 V Groove x2 Keyboard 2 Heater Keyboard 1 LCD screen Lashing eyelet Lashing eyelet Battery indicator push button Power supply connector...

Page 7: ...nace Menu for use based maintenance Sistema System configuration language screen power 4 1 Function Setting In this option the parameters shown below will be configurable Parameter Description Quick A...

Page 8: ...ows the modification of the enhanced duration of the arc usual value 1000ms It can be increased in case that after splicing there is narrowing detected on the fiber at the splicing spot If the fiber i...

Page 9: ...displayed Delete records Erases all the records that the device has registered Query fault records Displays the records of all the failed splices Delete fault records Erases all the records of the fa...

Page 10: ...be displayed on the screen The PC will show a new disc unit containing the folders below For downloading the records you must access the folder RECORD within the same SPLICE TXT is the file that cont...

Page 11: ...rrors Check the correct alignment of the electrodes and make sure their ends are in good shape Should you find any impurities take them away with a wipe swab dampened with isopropyl alcohol 5 2 Fiber...

Page 12: ...usly entered the Start menu with the Menu key The fusion splicer will not work unless you are on that menu Check the fibers hanging from the fusion splicer are not blocked by the cover or held by the...

Page 13: ...g a 45o angle with each other Note Apply a controlled force for the cleaning of the V groove It is a sensitive precision element 6 2 Cameras or lenses Clean the lenses regularly Presence of dirt on th...

Page 14: ...ting blade and by the means of a screwdriver pull out the screw 3 Replace the cutting blade and re assemble following the steps descrived above in reverse order 6 6 Stripper You should occasionally lu...

Page 15: ...Y axis 180x magnification X axis or Y axis separately 360 magnification Screen 4 3 high performance LCD Tensile test 2N standar Heat shrink protectors 60 50 45 40 30 and 25mm Electrode duration 3 000...

Page 16: ...www televes com...

Reviews: