background image

EN

w w w . t e l e v e s . c o m

DVB Meter / Analyser  

with digital processing

Refs. 593501, 593502, 593503, 593504, 593505

Instruction Manual

EN

Summary of Contents for H30Evolution

Page 1: ...EN w w w t e l e v e s c o m DVB Meter Analyser with digital processing Refs 593501 593502 593503 593504 593505 Instruction Manual EN ...

Page 2: ......

Page 3: ...tellite Test 15 6 Learning Plan 16 7 Constellation 16 8 Echoes 17 9 Video Camera 18 10 Wi Fi Scan 19 11 Setup 20 Firmware Update 21 Web Application 22 1 Measurements 22 2 Plans 23 3 SCR 24 4 Quality Profiles 24 5 Screen Mirroring 24 6 Clone 25 7 Update 25 Mobile Devices App 26 1 Connection between the App and the H30Evolution 26 2 Features 27 2 1 Loggers 27 2 2 Screen Mirroring 27 2 3 Files 28 2 3...

Page 4: ...e personnel Follow the instructions in this manual when replacing the battery Heat The product should be situated away from heat sources such as radiators heat registers stoves or other products that produce heat Do not place naked flame sources on the meter such as lighted candles Maximum current consumed by the meter 2A Battery Battery must be replaced by qualified personnel following the steps ...

Page 5: ...n measurements needed in today s fulfilment environment Key Features User friendly handheld DVB meter Complete portfolio of Analog Digital measurements with easy to read pass fail indicators Quick and easy to use interface with features such as Channel measurements System Scans Constellation Diagram Spectrum Analyzer Echoes Datalogger and more Rugged light weight fully automatic fast and accurate ...

Page 6: ...z Output 12VDC 2A Battery LiIon smart battery 7 2VDC 2300mAh Operating Time Up to 4 hours Operating Temperature 23ºF to 104ºF 5ºC to 45ºC Storage Temperature 4ºF to 158ºF 20ºC to 70ºC Humidity 5 to 95 non condensing Ruggedness Survives 1 m 3 ft drop to concrete on all sides Communication Interfaces USB 2 0 to download Datalogs and software updates Storage 400 MB internal for measurements Power up ...

Page 7: ... QAM B ITU J 83 B ref 593360 MPEG image Modulations 64QAM and 256QAM Power 45 110dBuV 25 120dBuV opt 593235 Pre BER y Post BER 1 0E 3 1 0E 8 MER Up to 38dB C N Up to 40dB Constellation Digital Measurements DVB S MPEG image Power 45 110dBuV 25 120dBuV opt 593235 CBER 9 9E 2 1 0E 6 VBER 1 0E 4 1 0E 8 MER Up to 20dB C N Up to 20dB Constellation Digital Measurements DVB S2 MPEG image Modulations QPSK ...

Page 8: ...r approximately 3 seconds 2 Back button Return to the previous menuorcloseaparameterentrywindow 3 Home button Return to the main menu 4 Navigation buttons Used to scroll through options 5 OK Button To confirm selection 6 Setup button Parameter window for the current function 7 LED Powering Indicates if the equipment is powering an external load 8 LED Charging Battery LED flashes while the battery ...

Page 9: ... 3 hour charge will provide approximately a 75 charge The charge management system will detect various conditions preventing charging such as a battery that is over a safe temperature About battery Important If the meter detects a shortcircuit or over consumption and it is not connected to the power supply it automatically shuts down To turn it on again it is necessary that it is connected to tyeh...

Page 10: ...t the bottom of the meter Carefully remove the connector from the power board and then remove the battery 3 sec OFF 3 sec OFF Place the new battery and then connect it to the power board Replace the back cover of the meter Make sure that the cable is not trapped between the two covers Replace the screws of the back cover 3 sec OFF 3 sec OFF 3 sec OFF ...

Page 11: ... Exten ded terrestrial input level range will be activated automatically in your H30Evolution whenever you register it within 30 days after you turn it on for the first time Product operation 1 Channel Info Analog and digital channels are very different in terms of signal content and power distribution and thus require the advanced SLM techniques provided in the Televes H30Evolution In analog mode...

Page 12: ...ering and DiSEqC In addition a SCR icon will be shown in the bar at the top SCR3 to indicate thar the slot is enabled While the slot is enabled all the setting changes of the meter will be applied to the currently slot SCR3 Tuning Channel Frequency A D Auto Analog Digital Save datalog Saves the current scan measurements You can see the datalogs using the remote control application 2 Spectrum Real ...

Page 13: ...elect the span to include a frequency range wide enough The audible signal becomes continuous when the signal leves is close to the reference level Then it is necessary to increase the reference level to get a more accurate adjustment This is a useful feature to point antennas without having to look at the display Span 5MHz 10MHz20MHz 50MHz 100MHz 200MHz 500MHz Full Set the span of the spectrum To...

Page 14: ...lan and detects every existing analog and digital channel in real time to determine the overall frequency response of the system The scan measurement leverages the location based thresholds to clearly show whether or not signal levels comply with the cable system s specifications with their green yellow and red bars This gives an easy to understand real time view of the system including the BER an...

Page 15: ...f channels showed in the bar graph Ref Level Select the reference level of the bar graph Save datalog Saves the current scan measurements You can see the datalogs using the remote control application 5 Satellite Test This function checks that the input signal corresponds to the selected satellite and at the same time checks the proper reception of the selected transponders from 1 to 4 transponders...

Page 16: ...ler white bar indicating the level of the audio carrier 6 1 Main window Below is a capture of a Learning Plan window with a brief explanation of its features List of measurements with pass fail indicators Bar graph representing found channels Color according to checkmarks Indicates that the scan is finished Press to save the plan Selected channel Change using 7 Constellation Digital video often do...

Page 17: ... the setting changes of the meter will be applied to the currently slot SCR3 Zoom OFF 1st 2nd 3rd 4th Select a quadrant of the constellation to be represented for more detailed view Select Zoom OFF for the full constellation Tuning Channel Frequency Save datalog Saves the current scan measurements You can see the datalogs using the remote control application 8 Echoes It is important to check that ...

Page 18: ... to digitize the analog input signals It is specifically aimed for installation and maintenance of analog video surveillance systems The supported interface is composite RCA S VHS The input video formats that can be displayed are the following NTSC 720x480 30fps PAL 720x576 25fps To run the feature you just have to connect the input signal to the adaptor provided with the H30Evolution making sure ...

Page 19: ...ed to which is the one that has more signal power at that point Power of each Wi Fi access point s signal The list is sorted by power Wi Fi network s channel Wi Fi network s name The red lock indicates that the network is locked Wi Fi network s MAC Wi Fi protect access type 5 4 2 Map view 5 4 3 Setup Press to change the Wi Fi Scan options Band Terrestrial Satellite Mode Selects between Map or List...

Page 20: ...ting locations Analog Standard Selects the standard for the analog channels and changes automatically the audio carrier to a value according to the selected standard Audio Carrier 4 5 MHz 5 5 MHz 6 0 MHz 6 5 MHz Volume Network Setup Manual Auto When Setup Manual is selected the user must set the gateway IP When Setup Manual is selected the user must set the IP DNS When Setup Manual is selected the...

Page 21: ...vice it will appear another line showing the MAC of the other device Time and Date Set current time hour and minutes and date day of the month month and year Energy Auto suspension Auto shutdown Update firmware See section Firmware update Reset configuration Resets the H30Evolution to factory settings Licenses Shows a list with all the licenses included in your H30Evolution About SW About HW Firmw...

Page 22: ...mode Datalogs list Select unselect all the Datalogs Remove export to xls Date of the measurement channel plan and Datalog name Channel measurements Filter according to channel type Web Application First of all connect your H30Evolution to the network using the Ethernet connector or the Wi Fi interface Then you must find out the IP of your H30Evolution see section 11 Setup Network Wi Fi Then type y...

Page 23: ...lable channel plans grouped by geographical areas Select the channels plans you want to upload to the meter 2 Plans In this window you can see all the channel plans of your H30Evolution They are grouped in three categories Terrestrial Satellite and Customer The Terrestrial and Satellite channel plan are the standard channel plans of the corresponding band These plans can be removed from the meter ...

Page 24: ...the multiswitch Add a new multiswitch Duplicate multiswitch Save multiswitch Type to edit 4 Quality Profiles Using the web application you can add new quality profiles The H30Evolution has two pre defined quality profiles head end and outlet that can not be edited but they can be duplicated The duplicated quality profiles are saved in the custom quality profiles and the custom quality profiles can...

Page 25: ...u H30Evolution in connected to the internet Click on the arrow to display menu Click to display the function the system will detect automatically if your meter is already updated by clicking on Last firmware version If it is not then you can download the new version and install it automatically from this menu If you get the update file from your distributor you can install it in your H30Evolution ...

Page 26: ...ttings function of your mobile device and turn Wi Fi ON and make sure that your H30Evolution Wi Fi is present at the networks list the name of the Wi Fi is H30Evolution followed by the serial number 3 Select to connect to your H30Evolution Wi Wi Fi name and connection key are shown Turn your mobile device Wi Fi ON Fi Your mobile device will ask for the key that is Televes1 4 Then open the H30Evolu...

Page 27: ...ill not be displayed either Tap on share Tap to delete Tap on the arrow button to display the keyboard Tapping on Info the user can see the following screen 2 Features Once your iPad and your H30Evolution are con nected you can operate with the App using the following features 2 1 Loggers This window shows the Logs saved in your H30Evolution When you tap on one of these logs to select it you will ...

Page 28: ...he keyboard Tap on key board buttons to manage the H30Evolution 2 3 1 Channel Plans Using this function of the App you can see all the channel plans of your H30Evolution as well as add new user channel plans and edit them The standard channel plans can not be edited The standard plans can be cloned When the user does this a new channel plan is added to the User channel plans list Enter the new use...

Page 29: ...he will be automatically loaded to the H30Evolution To delete a channel plan swipe to the left the corresponding line 2 3 2 SCR This function opens a web navigator with the web page of your H30Evolution and points directly to the SCR section See section 3 SCR of the Web Application 2 3 3 Quality Profile This function opens a web navigator with the web page of your H30Evolution and points directly ...

Page 30: ...ter it If you register your H30Evolution within 30 days you will get two options valued in 200 for free If you press BACK you can use your H30Evolution If you press OK it will begin the registration process The user can choose to use his her mobile phone to read the QR code or use the Register function of the H30Evolution App note the mobile device wich the app is running on must have access to th...

Page 31: ...e battery is about to finish The battery icon is red now It is recommended to connect the meter to the external power source LOW BATTERY Shutting down Some time after the LOW BATTERY message appears time varies depending on the functions used it will appear this message If the meter is not connected to the external power source it will switch off BAD POWER Unplug power source This message appears ...

Page 32: ...ir read the manual to ensure proper use and attempt to RESET the unit to clear any problems Repair service Do not return the unit without first contacting Televes Technical Support If the unit needs to be returned Televes will arrange for free shipping The unit will need to be appropriately packed for shipping In compliance with IATA Regulations when using our shipping service follow these instruc...

Page 33: ...e claimed defect and the invoice or other proof of original purchase date and price If Televes so requests the Purchaser shall at Purchaser s expense deliver the claimed Product s to Televes within 14 days of the date of the return authorization Under no circumstances shall the Product s be returned to Televes without a return authorization E Any refund to the Purchaser shall be limited to the pur...

Page 34: ...H30EVOLUTION handheld DVB meter Analyzer 34 ...

Page 35: ... CONFORMITY DECLARAÇÃO DE CONFORMIDADE DECLARATION DE CONFORMITE DICHIARAZIONE DI CONFORMITÀ DEKLARACJA ZGODNOŚCI KONFORMITÄTSERKLÄRUNG ΠΙΣΤΟΠΟΙΗΤΙΚΟ ΣΥΜΜΟΡΦΩΣΗΣ FÖRSÄKRAN OM ÖVERENSSTÄMMELSE ДЕКЛАРАЦИЯ СООТВЕТСТВИЯ نايب ةقباطملا www doc televes com ...

Page 36: ......

Page 37: ...593501_593502_593503_593504_593505_2 01_EN ...

Reviews: