ES
17
6. Annexes
6.1 Annex A (separate head):
Among the fusion splicer's accessories, you will find a spe-
cific head that will allow you to introduce a connector for
direct fusion (these connectors hide the fusion spot under
a cap they have on their rear) .
It is conceived to be interchanged with the head coming on
the cleaver and subsequently with one of the fibre clamps
existing on the fusion splicer . Follow these steps:
1
Extract the head in the cleaver .
2
Insert the connector on the head .
3
Install the new head on the cleaver (without screw) and
proceed with the cleaving .
4
Exchange the fibre clamp of the splicer with the new
head . To do this, extract the fibre clamp's screw and re-
move the clamp, as shown in the image .
5
Install the new head (without screw) .
6
Place the fibre on the right fibre clamp and proceed with
the splicing .
7
Proceed with the baking and mount the connector .
6.2 Annex B (Single-fibre tube):
In case you use a single-fibre tube (containing only one fi-
bre), you can strip it and directly insert it into the cleaver
and the splicer, as shown below: