Power Connections OBDII
47
Identifying correct wires
•
Remove any interior trim as necessary to gain access to the vehicles wiring as well as any areas where interconnecting wire harnesses
may be located.
•
Attach fuse holders to the Constant and Ignition wires of the TM470 power harness.
•
It is always recommended the installer locate the constant and ignition wires at the ignition switch. (This is not a given acceptable
location for connection. There may be extreme difficulties accessing the ignition switch wires, the wires may be low amperage control
wires not acceptable to power the TM470. In these cases the installers experience and knowledge will allow connections in other
appropriate locations.)
•
Always use a multimeter in identifying the appropriate wires following the guidelines on the next page.
•
All connections MUST be soldered (preferred) or poke and wrapped. Scotch-Loc, or T-Tap connections may not be used, if they are discovered
during a QC inspection they will be corrected and installer will be billed for repairs.
•
Use of supplied provided fuse holders is mandatory, their placement should be as close to the connection point in the vehicle as possible. These
fuses are provided to protect the vehicle not the TM470.
Summary of Contents for TM470 Series
Page 1: ...TM470 Installation overview 6 2 2016 www TeletracNavman com 1...
Page 6: ...TM470V6 6...
Page 18: ...TM470V8 18...
Page 36: ...TM470V8 HOS 36...
Page 59: ...TROUBLESHOOTING 59...