Qtanium 400 | Installation Manual
20
4.10
Test the Installation with OnlineAVL2/DIRECTOR
To check that the Qtanium 400 is installed correctly and can communicate with the
OnlineAVL2/DIRECTOR software:
1.
Position the asset outside in a location that provides a good view of the sky and
good cellular reception.
2.
Verify/record the asset’s name/number and calibrate engine hours in
OnlineAVL2/DIRECTOR (Device Properties).
3.
If the asset has a negatively isolated disconnect switch, toggle this to check that it
does not affect the Qtanium 400’s power supply. If it creates Power Up and Power
Removed events in OnlineAVL2/DIRECTOR, check the black wire (see section 4.6).
4.
Start the engine and allow up to five minutes to initiate OnlineAVL2/DIRECTOR
reporting.
5.
Check that OnlineAVL2/DIRECTOR shows an Ignition On event. If not, check the pink
wire (see section 4.5).
6.
While the engine is running, check the Satellites column in OnlineAVL2/DIRECTOR.
Five (or more) satellites are required. If the number of satellites is low, move the
asset and/or select a different location to mount the GPS antenna.
7.
Verify/configure sensor activity in OnlineAVL2/DIRECTOR for any sensors connected
to Digital Inputs, if applicable.
Note We recommend using a mouldable plastic sealant such as COAX-SEAL® around
the antenna connectors if the asset is used in a very dusty or very wet environment.
Although the Qtanium 400 has an IP-67 rating, it is considered best practice to protect
the RF connectors in this manner.