12
HouseControl E+ Installation Manual
Connect the device to the EXT relay. You can
use the relay, for example, for controlling
magnetic valve in water pipe and prevent water
damages.
Important: Make sure that max load 230VAC/6A is not exceeded under any circumstances.
Important: When relay is used to steer inductive load (for example, another contactor), connect
RC filter or EMC suppression component in parallel to load to stop voltage spikes when
contactor releases. Voltage spike may break the relay.
3.17 Power Supply and Battery Backup Unit
1. Connect the cable from the battery
backup unit to the +12V and GND
connectors as depicted in the separate
wiring diagram.
2. Connect the battery.
3. Attach the battery to the casing with two-
sided tape.
4. Connect the mains cable.
Make sure the HCE+ works even if you detach the mains cable from the wall outlet. This proves that the
battery has been connected properly and the 4A fuse is ok.
3.18 SIM Card
First, disable the PIN code request from the SIM card. Make sure the power is switched off from the
HCE+ (power switch is OFF, see picture below) and insert the SIM card in the SIM card slot in the
bottom right corner of the central unit. Switch power ON and leave the cover open. Wait 30 seconds for
the HCE+ to start up.
Picture 1
.
Opening the cover, location of the power switch, and the SIM card slot.
Wait 30 seconds after inserting the SIM card and powering up the unit. HCE+ goes into programming
mode and the unit’s status light starts blinking. If the light does not blink, make sure
the PIN code
Power switch
ON
OFF