INSTALLATION
9
Detach the cover of the motion sensor by opening the screw at the bottom.
Connect the motion sensor to the central unit as depicted in the separate
wiring diagram. It is recommended that you make the following adjustments
to the motion sensor:
-
Turn the red screw counter clockwise to 11 o’clock.
-
Change the Pet jumper to 25kg.
-
Change the Pulse jumper to place 2.
The motion sensor works best with these settings in domestic environment.
By turning the red screw clockwise you can increase sensitivity.
Attach the motion
sensor to a wall near
ceiling.
Hide the surplus of the cable.
Connect the motion sensor to the IR
connector as depicted in the separate
wiring diagram.
3.13 Smoke Detector
The smoke detector should be attached to the ceiling. Do not place the detector in a corner or cranny
because then it will not detect smoke so easily.
Note: You can connect up to 8 smoke detectors in the fire connector in HCE+.
Open the cover cerefully by using a
screwdriver.
Connect the installation cable to
the smoke detector as depicted
in the separate wiring diagram.
Place a battery in the detector. The
battery is used only when power
supply from HCE+ is cut off for some
reason.
Hide the surplus of the cable.
Connect the smoke detector to the Fire connector as depicted in the
separate wiring diagram.